If the appliance is connected directly to the circuit
breaker, fuse box or junction box, use flexible, armored
or nonmetallic sheathed copper cable (with grounding
wire). Supply a U.L listed strain-relief at each end of the
cable. At the appliance end, tile cable goes through the
Direct Connection
Hole (see Figure 5) on the Cord
Mounting
Plate. Wire sizes (copper
wire only} and
connections must conform to the rating of the appliance.
Where local codes permit
connecting
the appliance-
grounding
conductor
to the neutral
(white}
wire
(see Figure 6}:
(The 3-conductor
cord or cable must be replaced with a
4<onductor
cord or cable where grounding through the
neutral conductor is prohibited in new installations,
mobile homes, recreational vehicles or in other areas
where local codes do not permit neutral grounding)
1. Disconnect tile power supply.
2. In the circuit breaker, fuse box or junction box
connect the appliance and residence cable wires as
shown in figure 6.
White Wire
(Neutram)
Cable from
Residence
Black
WiresI
)n
Box
White Wire
(Neutral)
Green
U,L,-misted
(or Bare Copper)
Conduit
Wire
Cable from
Connector
Range
(or CSA misted)
Figure
6
3-Wire
(Grounded
Neutral}
Electrical
System
(Example:
Junction
Box}
Where tocaJ codes DO NOT permit connecting
the
appliance-grounding
conductor
to the neutral
(white}
wire, or if connecting
to 4-wire
electrical
system (see Figure 7}:
1.
Disconnect the power supply.
2.
Separate the green (or bare copper) and white
appliance cable wires.
3.
In the circuit breaker, fuse box or iunction box:
connect appliance and residence cable wires as
shown in figure 7.
Cable from
Green
Residence
Junction
(or Bare Copper)
Box
Red_
Wires
White
Wire
ack
Green
(or Bare Copper)
White
Wire
Wire
(Neutram)
U.Loqisted
Cable from
Conduit
Appmiance
Connector
(or CSA misted)
Figure 7 - 4oWire Electrical
System
(Example:
Junction
Box)