Appendix A Event Notification Message List
A.2 Message List
Event type
code
xx
M E1FF00
M E2070001
M E2070002
M E2070004
M E207000B
M E207000C
M E207000D
M E207000E
M E207000F
M E2070010
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
Trap
Maintenance
No.
Info
xx
7
E1FF00
PINNED DATA was cleared CM#
The pinned data was cleared.
xx
: CM module ID (10– 11) from which the pinned data
was cleared
m
: CM number (0 – 1) from which the pinned data was
cleared
v
: CPU number in CM
7
E2070001
NOT READY(01:Configuration Error)
The device is in Not Ready status.
Shipment settings (model setting) and configurations are
not applied.
7
E2070002
NOT READY(02:CM F/W Version Error)
The device is in Not Ready status.
Firmware version for the CM is not correct.
7
E2070004
NOT READY(04:Restore Fail)
The device is in Not Ready status.
Backup is successfully complete, but the restoration cannot
be performed.
7
E207000B
NOT READY(11:Power Off/Fail Incomplete)
The device is in Not Ready status.
Failed to power off. Or the device power turns off
immediately after the device powers on.
7
E207000C
NOT READY(12:Backup Fail)
The device is in Not Ready status.
Backup failed.
7
E207000D
NOT READY(13:Multi CM Down)
The device is in Not Ready status.
Adjoining CMs with LUs are degraded.
7
E207000E
NOT READY(14:Machine Down Recovery End)
The device is in Not Ready status.
Machine down recovery is performed.
7
E207000F
NOT READY(15:Machine Down Recovery Failed)
The device is in Not Ready status.
Failed to perform machine down recovery.
7
E2070010
NOT READY(16:DE Build Error)
The device is in Not Ready status.
Failed to configure DE because of QSFP cable errors or FC
cable errors.
130
Copyright 2013 FUJITSU LIMITED
Upper: Message
Lower: Description
m
v
-CPU#
Remarks
This message is
notified when
"Pinned data" is
enabled for Error
Severity Level in the
event notification
setting.
Although this
message is notified as
an error message, no
further action is
required because this
message simply
means that pinned
data has been cleared
(normal).
This is not notified
during maintenance
operations.
These messages are
notified when "Not
ready" is enabled for
Error Severity Level in
the event notification
setting.
They are not notified
during maintenance
operations.
P3AM-4842-12ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents