RFID Demo Application
4 - 7
Registry File Example
Table 4-1
; *****************************************************************************************************
; RFIDDemo Registry File. This file will restore the demo settings after a cold boot.
; If you edit this file, the settings will not take affect until a cold boot occurs. Alternatively,
; on some Symbol Terminals, the registry file can be launched. When this is done, you will be
; prompted whether or not you want to merge these settings into the registry. The next time the demo is
; launched, it will use the settings in this file. (Make sure you are not running the demo when you do this!!!)
; The Gemini_RFID.exe demo also uses many of these registry settings, and in fact, can be used to registry settings
; (Also, make sure RFIDDemo is not running when launching the Gemini_RFID.exe demo.)
;
; NOTE: ALL DWORD VALUES NEED TO BE IN HEX NOTATION.
; *****************************************************************************************************
[HKEY_LOCAL_MACHINE\SOFTWARE\SYMBOL\RFIDDemo]
; If 1, then beep on all tag reads. If 0, do not beep.
"RFIDDEMO_BEEPER_ENABLED"=dword:1
; If 0, the demo will read continuously.
"RFIDEMO_AUTONOMOUS_MODE_ONTIME"=dword:000061A8
; If 0, the demo will read continuously. Otherwise, it will stop for this many ms.
"RFIDEMO_AUTONOMOUS_MODE_OFFTIME"=dword:00000000
; If 1, the demo will start reading automatically after finding a RFID reader.
"RFIDEMO_READ_TAGS_ON_LAUNCH"=dword:0
; If 1, the demo will start automatically upon the next warm or cold boot of the device.
"RFIDEMO_START_APP_ON_BOOT"=dword:0
; Any number less than 16 is a com port number. Greater than 16 is a TCP/IP port number.
"RFIDEMO_LOGGING_PORT_NUMBER"=dword:00000000
; Com Port baud rate for logging tags. Not used for TCP/IP connections.
; Common baud rates are:(USE HEX) (9600 = hex 2580) (38400 = hex 9600) (115200 = hex 1C200).
"RFIDEMO_LOGGING_PORT_BAUDRATE"=dword:00000000
; Name of port where logging will occur. For COM ports, use COM1: COM2:, etc...
; For TCP/IP Ports, use valid IP address, i.e. 192.168.1.1 localhost www.mysitename.com...
"RFIDEMO_LOGGING_PORT_NAME"=""
"RFIDEMO_LOGGING_TO_FILE"="1"
; If this is set, then the demo will attempt to contact an RFID reader at this port. (3000 is BB8 in hex)
"RFIDDEMO_READER_IP_PORT"=dword:00000000
; RF OnTime
"RFIDDEMO_READER_RF_ONTIME"=dword:0000003C