HP 3PAR StoreServ 7200 2-node Manual page 50

Hp 3par-to-3par storage peer motion guide (os 3.1.2 mu2) (ql226-97008, june 2013)
Hide thumbs Also See for 3PAR StoreServ 7200 2-node:
Table of Contents

Advertisement

Column
Mode
Partner
Partner WWN
Failover State
The detail pane contains the following information:
Group
General
Settings
(displayed for
FC and RCFC
ports)
IP Settings
(displayed for
RCIP and
iSCSI ports -
not shown)
50
Using the Peer Motion Manager
Description
Port firmware mode setting: Initiator, Target, Peer, or Suspended. Ports in Initiator mode
are connected to drive cages and ports in Target mode export to hosts. Suspended
mode is for target ports that have not yet been initialized by the system (this is rare).
Peer mode is for Ethernet ports.
The partner port, in Node:Slot:Port format. (Displayed only on destination systems.)
The WWN of the partner port. (Displayed only on destination systems.)
Indicates whether the system is in a failover state. (Displayed only on destination systems.)
Field
Description
Position
The port location in Node:Slot:Port format.
Port WWN
The port's World Wide Name.
Node WWN
The node's World Wide Name.
Type
Indicates whether the port is FC, iSCSI, RCIP, or RCFC.
Rate
The rate that data can be transferred over the port (1 Gbps, 2 Gbps or 4 Gbps).
When there is no specified value, no connection exists.
Connected Device
The type of device that the port is connected to: Host or Peer.
Type
Connected Device
The name of the system associated with the selected port.
Mode
Port firmware mode setting. Ports in Initiator mode are connected to drive cages
and ports in Target mode export to hosts. Suspended mode is for target ports that
have not yet been initialized by the system (this is rare). Peer mode is for Ethernet
ports.
State
The current state of the port.
MAC (not shown)
For iSCSI ports. The MAC address for the Ethernet interface.
TPGT (not shown)
For iSCSI ports. The Target Portal Group Tag for the iSCSI target portal group.
Connection Mode
The type of port connection: Host or Peer.
Connection Type
Connection type or port connection setting: Loop or Point.
Configured Rate
Data transfer rate setting (for example, 1 Gbps). Auto indicates that the system
automatically selects the rate.
Max Rate
Maximum rate of connection from the port.
Class 2
Indicates whether Fibre Channel service Class 2 is Disabled, Ack 1 or Ack 0.
VCN
For fabric attached ports, indicates the VLUN change notification setting. When
set to Enabled, notices are generated and sent to the fabric controller. When set
to Disabled, no notification is sent.
Unique Node WWN
Indicates whether the node's WWN is Enabled or Disabled.
Interrupt Coalesce
If disabled, each I/O generates a separate interrupt to the HBA port driver rather
than generating one interrupt for multiple I/O completion.
MAC
For RCIP ports, the MAC address of the Ethernet interface.
DHCP
For iSCSI ports, indicates whether the DHCP protocol is enabled.
IP Address
IP address of the iSCSI or RCIP port.

Advertisement

Table of Contents
loading

Table of Contents