Chapter 4 System Configuration
4.5 Hot Spares
When multiple Global Hot Spares are installed, the following criteria are used to select which hot spare will
replace a failed drive:
Table 4.9
Selection
order
1
2
3
4
*1:
When there are multiple hot spares with a larger capacity than the failed drive, the hot spare with the smallest
capacity among them is used first.
Hot spare selection
A hot spare of the same type, the same capacity, and the same speed as the failed drive
A hot spare of the same type, a larger capacity, and the same speed as the failed drive (*1)
A hot spare of the same type, the same capacity, and a different speed to the failed drive
A hot spare of the same type, a larger capacity, and a different speed to the failed drive (*1)
ETERNUS DX80 S2/DX90 S2 Disk storage system Overview
Copyright 2013 FUJITSU LIMITED
Selection criteria
47