Bosch D9210C Program Entry Manual page 11

Access control interface module
Table of Contents

Advertisement

Access Control Interface Module
Yes Programmed shunt time will activate so door can be manually opened.
No Request to Enter [RTE] automatically activates the programmed strike and shunt time.
NOTICE!
Use this parameter when a user can open a door manually without relying on a token/card to
activate the strike (such as with a "push bar").
NOTICE!
When RTE Shunt Only is [Yes] Request To Enter events are not logged, reported, or printed.
D# REXShunt Only?
Default:
Selections:
Use this program item to disable the strike, but still activate the programmed shunt time upon
a Request to Exit an area.
Yes Programmed shunt time will activate so door can be manually opened.
No Request to Exit [REX] automatically activates the programmed strike and shunt time.
NOTICE!
When REX Shunt Only is [Yes] Request To Exit events are not logged, reported, or printed.