Figure 2: Wiring Diagram For Typical D9210B Installation; D9210B Operation And Installation Guide - Bosch D9210B Operation And Installation Manual

Access control interface module
Table of Contents

Advertisement

EMERGENCY EGRESS Switch should be
Normally Open (NO) for Coil Locks and
Normally Closed (NC) for Maglocks
EMERGENCY
EGRESS
Security
Panel
SDI
PWR
SDI
(white/yellow)
A
SDI
(green)
B
SDI
COM
(black)
DOOR CONTACT
(NORMAL E.O.L.
IN CIRCUIT)
1K
E.O.L.
DOOR
CAUTION
© 2002 Bosch Security Systems
Strike and
D9210B
12 VDC AUX
Power Supply
UL Listed for Fire
DC OUTPUT
-
+
(red)
(black)
TAMPER SWITCH
(NORMAL OPEN)
RTE/REX
(NORMAL
OPEN)
12 VDC READER
12 VDC
DOOR
STRIKE
Note:
This color code does not match
all readers. Make a note of the
color code of the reader you are
using.
Some jurisdictions will not allow the
use of Emergency Egress as your sole
means of escape. If this feature is used,
it still may be necessary to provide listed
panic hardware. Consult your local
authority having jurisdiction (AHJ) prior to
nstallation.

Figure 2: Wiring Diagram for Typical D9210B Installation

D9210B Operation and Installation Guide

CAUTION
DO NOT power the
D9210B Module
with 24 VDC.
1
PWR +
2
LCKN/C
3
LCKCOM
4
LCKN/O
5
COM
6
SDIA
7
SDIB
8
T +
9
ZNCOM
10
ZN +
11
RTE
12
COM
13
REX
(black)
14
(red)
+5.20V
(green)
15
DATA 0
(white)
16
DATA 1
17
(yellow)
BUZZER
(brown)
18
LED
(+)
(-)
12 VDC
BUZZER
OPER
MON
D0
READER
D1
READER
NOTE:
A 24 VDC power supply may be used for the door
strike if necessary. (See Figure 5)
Page 15
D9210B
Installation
D9210B
ON
1
2
3
4
5
6
32206G

Hide quick links: