Attaching The Module To The Enclosure Door; Separate Enclosure Mounting; Optional Mounting Plate; Attaching To Enclosure Door - Bosch Conettix C900V2 Installation Manual

Dialer capture ethernet module
Hide thumbs Also See for Conettix C900V2:
Table of Contents

Advertisement

.
Figure 2:

Optional Mounting Plate

A
6
5
3. Place the top edge of the C900V2 (4) under the
standoff bracket of the top two standoffs (1).
4. Insert two of the Phillips
(5) through the holes in the top standoffs (3).
5. Lower the bottom edge of the module to rest
against the ledge of the two bottom standoffs (2).
6. Insert the other two Phillips head screws (5) into
the bottom two mounting holes (6) on the C900V2
and through the bottom two plastic standoffs (2)
and mounting bracket (3).
7. Tighten the screws until the C900V2 is attached
securely to the mounting plate.
2.1.2
Attaching the Module to the Enclosure
Door
Refer to Figure 3.
Figure 3:

Attaching to Enclosure Door

2
1. Slide the tabs (1) at the top of the mounting plate
over the top lip of the enclosure door (2).
2. Position the mounting plate on the side farthest
from the door hinge.
Bosch Security Systems, Inc. | 8/08 | F01U087780-01
3
1
2
4
6
®
head screws provided
1
Conettix C900V2 | Installation Guide | Contents
2.1.3

Separate Enclosure Mounting

You can mount the C900V2 in a separate enclosure
such as the AE2. Refer to Figure 4.
Mount the enclosure on a vertical
surface before you install the C900V2
because the C900V2 covers one of the
mounting holes (9).
1. Place the top edge of the C900V2 (1) between the
3
two slots (2) on the inside top of the enclosure (3).
2. Insert the top hook of the top plastic standoffs (4)
into the mounting brackets (5) on the back wall of
the enclosure (6), showing a side view of the
standoff in the mounting bracket).
3. Align the bottom two mounting holes (7) on the
C900V2 with the plastic standoffs (4) and the
enclosure mounting brackets (5).
4. Insert two screws (8) into the holes and slowly
tighten until the C900V2 is secured firmly to the
enclosure.
Figure 4:

C900V2 in AE2 Enclosure

2
3
8
1
7
4
5
9
6
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents