Troubleshooting - Kenmore Sears 758.144071 Quiet comfort Owner's Manual

Whole house humidifier 7 gallon output
Table of Contents

Advertisement

144070
hum.
manual
11/20/00
11:48
AM/_Page
13
Troubleshooting
Trouble
Probable
Cause
Remedy
Unit will not run and Fill
• Selected
humidity
level
• Raise
humidistat
setting.
Light
is not on.
has been
established.
• No Power.
• Check
120 volt power
source.
Unit will not shut off.
• Float
is not free.
• Free float from obstruction.
Unit will not dry out
• This is normal.
• A small
amount
of water
completely,
remains
in the cabinet
after the Fill Light comes
on.
Bottle
continues
to empty.
Unit is not emptying
during
use.
Unit runs and shuts off
before
bottle is empty.
• Air is entering
water
bottle.
• Dirty filters
• Bottle
cap plunger
missing
post in bottom
of cabinet
• Unit is not set up on a
level surface.
(Float
will
not sense
water
at the rear
of the cabinet.)
Check
"E-Z-Fill
Side-Cap"
and valve
assembly
cap to
ensure
tightness.
Check
for leak in water
bottle.
Ensure
gasket
for "E-Z-
Fill Side Cap" is in place
(see repair
parts
list).
Change
to fresh
new fil-
ters.
Check
orientation
of bottle.
Reposition
so that bottle
cap plunger
is depressed
by post in bottom
of cabi-
net.
Position
unit level.
(Some
carpet
padding
may allow
unit to sit lower on the left
side than the right side
due to the weight
of the
water
bottle
on left side.
Install
coasters
under
left
caster.)
CAUTION: Use only 42-14900 EPA Registered Bacteriostat available
from Sears
Retail store.
Use of other water treatment products may damage the filter elements.
Under no circumstances
should you use water treatment
products designed for
Roto belt or Ultrasonic humidifiers.