Installation
Instructions
INSTALLING THROUGH THE WALL
Read these instructions
completely
and carefully.
ITI PREPARE OPENING IN WALL
Make certain a wall receptacle is available close
to the hole location or make arrangements
to install
a receptacle.
The cord length for the 11S-volt models is 72"
to the right and 47" to the left.
For the 230/208-volt
models the cord length is 65"
to the right and 39" to the left.
1-21SUPPORT REQUIREMENTS FOR AIR
CONDITIONER
The air conditioner wall case may be installed
with 1/4" min. extension out from the inside wall
or with 1/4" min. extension out from the outside wall.
The finished sides of the opening should be structural
wall members.
Lintel - Use a lintel in brick veneer and brick
and block types of wall to support the bricks
or blocks above the opening. Do not allow the wall
case to be used in lieu of a lintel.
Flashing - Install flashing (drip rail) as shown
to prevent water from dripping inside the wall
and down the outside of the building.
Brick veneer
Lintel a ngle_..
_
,
Jl_
(if required)
_
_b_-_d/
'i
ii/lll!l --
Plaster l ine
Caulking
l_=-_
i i
_;
on the outside _
_
Trimmolding
andinside
(if desired)
of the case)
Caulking
(above
Roomside
,rand below
Flashing ___)
(driprail)
|
|
!
1/4" rain.extension --
insidethe wall from
the trim molding
131 SUPPORT REQUIREMENTS FOR AIR
CONDITIONER
Mortar between the case and the brick wall around
the case may be undercut at about 45 ° for
improved caulking.
Inside
Topof case
/'
y_
Outside
Caulking --
Undercut
mortar
15