Installation
Instructions
Air Conditioner
1"-#1 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
I
BEFOREYOU BEGIN
Read these instructions completely
and carefully.
•IMPORTANT- save these
instructions
for local inspector's use.
"IMPORTANT
- Observe all governing codes
and ordinances.
• Note to Installer - Be sure to leave these instructions
with the Consumer.
• Note to Consumer - Keep these instructions
for future reference.
• Skill level - Installation of this appliance requires basic
mechanical skills.
• Completion time - Approximately 1 hour
• We recommend that two people install this product.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation
is not covered under the Warranty.
(b
©
@
ELECTRICALREQUIREMENTS(cont.}
Do not change the plug on the power cord of
this
air conditioner.
Aluminum
house wiring may present special
problems-consult
a qualified electrician.
Some models require 230/208-volt a.c.,protected with a time
delay fuse or circuit breaker.These models should be installed
on their own single branch circuit for best performance and to
prevent overloading house or apartment wiring circuits,which
could cause a possiblefire hazard from overheating wires.
IMPORTANT!
GE strongly recommends the removal of the old well case
end the installation of a new GEWell Case. If you decide to
keep the existing well case, you may need a kit to ensure
proper performance. If you DO NOT use a kit, you run the
risk of poor performance or product failure. This is not
covered under the terms of the GE warranty.
Air conditioner
break-in
period
NOTE - As with any mechanical
device with moving
parts, this unit will have a wear-in period. AFTER
INSTALLATION, this unit should be operated for 48
hours to achieve optimum
efficiency.
_
ELECTRICAL REQUIREMENTS
-&WARNING! Risk o felectric s hock. Can
cause injury
or death. This appliance
must be
properly
grounded.
Where a 2-prong
well outlet
is encountered,
it is your responsibility
end
obligation
to have it replaced
with a properly
grounded
3-prong
outlet.
Some models require a 115/120-volt a.c.,
60-Hz grounded outlet protected with a
15-amp time delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility of
electric shock hazard. If the wall outlet you plan to use
is only a 2-prong outlet, it is your responsibility to have it
replaced with a properly grounded 3-prong wall outlet.
Do not, under any circumstances,
cut or remove
the third (ground) prong from the power cord.
J-MODEL QUALIFYING QUESTIONS
J-model air conditioners may fit in existing wall cases.
However, they often need a kit to properly adapt the case
to the GE air conditioner. Answer these questions and see
the chart on the next page for the proper kit.
[]
What brand air conditioner will you be replacing?
[]
What ere the dimensions of the well case currently
m use?
r_
Whet is the model number of the chassis
currently in use?Whet is the model (or Type} number
of the well case currently in use?
Frequently, the J-model adapter kit will apply to another
brand model "series"or specific vintage. In these cases,
you need the chassis model number and/or the wall
case or "type" number to confirm the use of the correct
adapter kit.
r_
What type of outdoor grille is used with the current
wall case?
Theremay beanarchitectural g rilleattachedto a wall
caseto enhancethe exteriorappearanceof the building.
Customgrillesmay beusedwith J-modelwallcases
provideda J-modeladapterkit isalsousedto ensure
properairflow.
12