Code No.
4900H to 6999H Read parameters (RAM)
Write parameters
A900H to
C999H
(EEPROM&RAM) *
* The Life of EEPROM is approximately 100,000 times. Avoid writing a command more than 100,000 times
to
the same parameter of the drive and the option module.
Item
To read parameters a900 to c999, 6000H is subtracted
from the parameter number.
(Ex:
To write parameters a900 to c999, the parameter
number doesn't change.
(Ex: A900 -> A900H, C123 -> C123H)
- 29 -
Description
A900  A900H – 6000H = 4900H,
C123 -> C123H – 6000H = 6123H)
E658130