4.5
TRS / ARS Programming
T
RS Denied Code Entry for Levels 2 through 6
Description
Selection
Default
Programming
Conditions
Feature References
These allow you to specify the numbers which are toll-restricted for
each toll restriction level as follows:
Program [301]: restricts levels 2 through 6
Program [302]: restricts levels 3 through 6
Program [303]: restricts levels 4 through 6
Program [304]: restricts levels 5 through 6
Program [305]: restricts level 6
• Location number: 01 through 20
• Toll call number: 10 digits (max.)
All locations – Not stored
1.
Enter a program address (301 through 305).
Display example: 301 TRS DENY L–2
2.
Press NEXT.
Display: Location NO?
3.
Enter a location number.
To enter location number 01, you can also press NEXT.
Display example: 01:Not Stored
4.
Enter a toll call number.
To delete the current entry, press CLEAR.
To change the current entry, press CLEAR and enter the new number.
5.
Press STORE.
6.
To program another location, press NEXT or PREV, or
SELECT and the desired location number.
7.
Repeat steps 4 through 6.
8.
Press END.
• There is a maximum of 20 toll call numbers which can be restricted for
each program. Each number has a maximum of ten digits, consisting of
0 through 9, and
. The character " " can be used as a wild card
character.
• Programs [306]–[310] "TRS Excepted Code Entry for Levels 2 through
6" are used to assign exceptions to these numbers. Programs
[500]–[501] "Toll Restriction Level — Day / Night" are used to set the
toll restriction value for each COS.
Section 3, Features
Toll Restriction
301-305