Chapter 2 Basic Operation
2.2 Using the FUNCTION Button
2
3
4
5
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
Change the status of the ETERNUS DX Disk storage system to maintenance
status.
Use the pin that is provided with the ETERNUS DX Disk storage system to push down the
FUNCTION button for three seconds.
The ETERNUS DX Disk storage system is in maintenance status when the MAINT/ID LED
is green.
Use the FUNCTION button to change the following settings:
•
Switching the Master CM to the other controller for a dual-controller type
Use the pin to push down the FUNCTION button twice within three seconds.
The MASTER LED for the controller that is set as the Master CM is green.
•
Restoring the factory default settings of the LAN ports
Use the pin to push down the FUNCTION button three times within three seconds.
After the default settings of the LAN ports are restored, the MAINT/ID LED blinks green
for a few seconds.
Release maintenance status.
Use the pin to push down the FUNCTION button for three seconds.
The ETERNUS DX Disk storage system is not in maintenance status when the MAINT/ID
LED is off.
Attach the flange cover.
Copyright 2011 FUJITSU LIMITED
39
End of procedure
P3AM-4842-01ENZ0