Hitachi L300P Series Instruction Manual page 98

Three-phase input 200v class; three-phase input 400v class;
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

3–26
"A" Group: Standard Functions
Output frequency
% of target
100
96.9
82.4
17.6
Func.
Name
Code
A131 Acceleration curve
constants setting
A132 Deceleration curve
constants setting
The acceleration and deceleration curves can deviate from a straight line to a varying degree.
Parameters A131 and A132 control the amount of deviation for the acceleration and decelera-
tion curves respectively. The following graphs show intermediate output frequency points as a
percentage of the target frequency, for 25%, 50%, and 75% acceleration time intervals.
3.1
25
50
75
time
"A" Function
Description
Sets the curve deviation
from straight-line accelera-
tion in ten levels:
01 smallest deviation
10 largest deviation
Sets the curve deviation
from straight-line decelera-
tion in ten levels:
01 smallest deviation
10 largest deviation
Output frequency
% of target
100
99.6
93.8
87.5
68.4
64.6
35.0
25
50
75
time
Defaults
Run
Mode
Edit
–FE2
–FU2
Lo Hi
(EU)
(US)
✘ ✔
02
02
✘ ✔
02
02
Output frequency
% of target
100
65.0
35.4
31.6
12.5
6.25
0.39
25
50
75
SRW Display
Units
–FR
(JP)
02
>A131 ACCEL
GAIN
02
>A132 DECEL
GAIN
time
02
02

Advertisement

Table of Contents
loading

Table of Contents