314
Error
The indicated FRU has failed or is not operating correctly. This event follows some other FRU-specific event
indicating a problem. This event was defined for HP Remote Insight Support tools.
Recommended actions
To determine whether the FRU needs to be replaced, see the topic about verifying component failure in
the component's replacement instructions document.
315
Critical
The controller module is incompatible with the enclosure. The controller will automatically shut down. If two
incompatible controllers are inserted at the same time, or booted at the same time, one controller will crash
and the other will hang. This behavior is expected and prevents data loss.
Recommended actions
Move the controller module to a compatible enclosure.
316
Warning
The temporary license for a feature has expired. Any components created with the feature remain
accessible but new components cannot be created.
Recommended actions
To continue using the feature, purchase a permanent license.
Info.
The temporary license for a feature will expire in 10 days. Any components created with the feature will
remain accessible but new components cannot be created.
Recommended actions
To continue using the feature after the trial period, purchase a permanent license.
317
Error
A serious error has been detected on the back-end host adapter. The controller will be killed by its partner.
Recommended actions
See
Resources for diagnosing and resolving problems
318
Error
A hardware failure occurred: XOR error.
Recommended actions
Replace the controller module reporting the event.
319
Warning
The indicated available disk has failed.
Recommended actions
Replace the disk.
322
Warning
The controller has an older Storage Controller (SC) version than the version used to create the CHAP
authentication database in the controller's flash memory.
The CHAP database cannot be read or updated. However, new records can be added, which will replace
the existing database with a new database using the latest known version number.
Recommended actions
Upgrade the controller firmware to a version whose SC is compatible with the indicated database
version.
• If no records were added, the database becomes accessible and remains intact.
• If records were added, the database becomes accessible but contains only the new records.