Chapter 8: Server Management
Figure 8-10. Removing the Power Distribution Board (T-Docking)

Installing the Power Distribution Board (T-Docking)

To install the Power Distribution Board (T-Docking), complete the following procedure:
1. Remove the U-shaped handle on the original Power Distribution Board (T-Docking) and attach
it to the replacement board.
2. Place the Power Distribution Board (T-Docking) into position, taking care to locate the board
over the indexing stake in the middle and not over the SCSI cable.
3. Engage the connector on the side of the Power Distribution Board (T-Docking) to the
Sideplane. Be sure that the connector on the Power Distribution Board (T-Docking) is aligned
correctly with the Sideplane before pressing the board down.
4. Connect the 172 mm fan cables to the underside of the Power Distribution Board (T-Docking).
You can make the connection through the emptied Hard Drive Bay.
5. Reinsert the Hard Drive Bay and secure the four front screws.
6. Reinsert the two hot swap drives into the Hard Drive Bay.
7. Connect the Internal SCSI cable to the I/O Baseboard.
8. Install the 120 mm fan cable into the top of the Power Distribution Board (T-Docking).
9. Connect the DC-DC converter to the top of the Power Distribution Board (T-Docking).
10. Connect AC input cables to both connectors on the AC Power Distribution bracket.
11. Align the AC input bracket and install the two screws to secure it.