HP AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive Installation Manual page 23

Modular smart array
Hide thumbs Also See for AD510A - StorageWorks Modular Smart Array 1500 cs 2U Fibre Channel SAN Attach Controller Shelf Hard Drive:
Table of Contents

Advertisement

Table 2: MSA1500 and SAN-related websites
website
HP MPIO Basic Failover
http://h18006.www1.hp.com/
products/sanworks/
multipathoptions/index.html
QLogic Driver for HBA Control
and Multipathing
http://h18006.www1.hp.com/
products/sanworks/
multipathoptions/index.html
Emulex MultiPulse Path Failover
for Linux
www.hp.com/go/san
Array Configuration Utility
(ACU)
Array Configuration Utility -
Command Line Interface
(ACU-CLI)
h18000.www1.hp.com/products/
servers/proliantstorage/
software-management/acumatrix/
index.html
HP StorageWorks 1500 Modular Smart Array Installation Guide
Multi-pathing software for Windows (active/passive environments
only)
Used in multi-pathing environments running
controller firmware, HP MPIO Basic Failover provides basic path
failover and path recovery.
Other multipath software already present on the host may not be
compatible with HP Basic MPIO. See the MSA1500 compatibility
guide for details.
Multi-pathing tool for Linux (active/passive and active/active
environments)
Used in multi-pathing environments running either active/passive
or active/active firmware, QLogic Driver for HBA Control and
Multipathing provides multipathing support for Linux environments.
This multipathing tool is included with the QLogic HBA driver on
the MSA Support Software CD.
Multi-pathing tool for Linux (active/active environments only)
Used in multi-pathing environments running active/active
firmware, Emulex MultiPulse provides multipathing support for
Linux environments.
MultiPulse is included with the Emulex Linux HBA driver on the
MSA Support Software CD.
Note:
Emulex MultiPulse is supported for use with Linux kernel 2.6
or later only. No support is provided or planned for earlier Linux
kernels.
Storage configuration software (active/passive and active/active
environments)
The Array Configuration Utility (ACU) is a server-based,
browser-accessed tool used to configure an array controller and its
storage. The ACU can be used in Windows, Linux, and NetWare
environments. (NetWare environments run the ACU directly from
the MSA Support Software CD.)
The Array Configuration Utility-Command Line Interface (ACU-CLI)
is a command line interface used to configure an array controller
and its storage. The ACU-CLI is primarily used in HP-UX
environments.
These utilities are provided on the MSA Support Software CD.
Installation Procedures - All Deployments
Content
active/passive
array
23

Advertisement

Table of Contents
loading

Table of Contents