Managing Unused Ports; Changing The Host Port Connectivity - HP 6400/8400 User Manual

Enterprise virtual array
Hide thumbs Also See for 6400/8400:
Table of Contents

Advertisement

Table 10 Maximum LUN size (continued)
Operating system
HP-UX 1 1.1 1
HP-UX 1 1.23
HP-UX 1 1.31
IBM AIX 5.2
IBM AIX 5.3
IBM AIX 6.1
Mac OS X 10.x
Mac OS X 1 1.x
Microsoft Windows Server 2003
Microsoft Windows Server 2008
Red Hat Linux 3, 4, and 5
SUSE Linux Enterprise Server 8, 9, and 10
Sun Solaris 8, 9, and 10
VMware ESX 3.0.x and 3.5
Citrix Xen

Managing unused ports

When you have unused ports on an EVA, perform the following steps:
1.
Place a loopback plug on all unused ports.
2.
Change the mode on unused ports from fabric to direct connect.

Changing the host port connectivity

To change the host port connectivity:
1.
Disconnect any connected cable.
NOTE:
restart to clear the condition.
2.
Use the OCP and navigate to the host port to be changed.
3.
Select fabric for an FC switch connection or direct for direct attachment to an HBA.
4.
Reconnect cables.
36
EVA6400/8400 operation
Failing to disconnect the cable prior to making the change will require a controller
Maximum LUN size
2 TB
2 TB
16 ZB
1 TB (AIX 5.2ML06 or earlier)
2 ZB (AIX 5.2ML07 or later)
1 TB (AIX 5.3ML02 or earlier)
2 ZB (AIX 5.3ML03 or later)
2 ZB
Less than 32 TB
Less than 32 TB
256 TB
256 TB
Maximum supported block device at 16 TB as of RH5.1
Maximum block device size is 16 TB for 32-bit system and
8 iEB for 64-bit systems
2 TB
2 TB
Maximum supported block device at 16 TB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 6400Storageworks 8400

Table of Contents