Figure 26 I/O tab of Disk Enclosure Properties window
NOTE:
The Firmware revision fields are different for EVAx400 and P6000 disk
enclosures.
If the fields Assembly serial number, Hardware revision, and Hardware type on the I/O
tab of the Disk Enclosure Properties window are blank, you can optionally reset the I/O
modules to clear the blank fields after the I/O module firmware upgrade has completed
successfully. Note that blank fields do not affect the array's ability to process host I/O.
See
"Resetting the I/O module" (page 56)
e.
Check the operational states that you recorded and proceed as follows:
Good: No action
Loading firmware: The I/O module firmware load is blocked. Corrective action is
required somewhere on the array (but not on this I/O module). Continue with
16
Any state other than Good or Loading firmware: Corrective action is required on
this I/O module. Continue with
16. Check the event log for the code-load-blocked code (066df308, critical event). If you do not
see this event, contact your HP-authorized service representative for assistance. If you see this
event, continue with
Step
Step
17.
for more information.
16.
Step 5. Upgrading the controller software
Step
55