Updating Of A Single Net Variable - Philips SPENDEX 40 Operating Instructions Manual

Speech encryption decryption equipment
Hide thumbs Also See for SPENDEX 40:
Table of Contents

Advertisement

SPENDEX 40 UA 8251/01
NATO RESTRICTED
OPERATING MANUAL
5.7
Updating of a Single Net Variable
The selecting of a single Net variable takes place on dialling in
the compartment number under which the key variable is stored.
Furthermore the possibility is provided of putting in also the number
of update steps by dialling in the desired update number.
Actions
LED
D i s p l a y
Remarks
Start conditions:
- Terminal on hook
- CIK module connected
• • *
• •
1. Dial in code 24111.
2. Press * key.
3. Dial in compartment
number (00...19).
4. Dial in the new update
number, unless one
update step is
required.
5. Press P key.
6. Press DTE key.
"UPD XX? "
"UPD AB "
"U AB.ZZ "
"U AB.FF "
"AB ZZ-FF"
"ABYYYYFF"
The digits do
not become
v i s i b l e .
See Note 1.
See Note 1.
Update action
successful. See
Note 2.
AB = compartment number (AB = 00...19)
F F = n e w u p d a t e n u m b e r
YYYY = control group (Y = A...P)
Z Z = p r e v i o u s u p d a t e n u m b e r ( Z Z = 0 1 . . . 9 9 )
Note 1: The update procedure can be interrupted by pressing the DTE
key. Then the terminal returns to the start condition and
" * " a p p e a r s i n t h e d i s p l a y a g a i n .
Note 2: After the update action the terminal remains in the update
substate. Another compartment can now be selected by dialling
in a new compartment number immediately.
9922 154 13061
5-6
NATO RESTRICTED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ua 8251/01

Table of Contents