HP 3314A Manual page 41

Function generator
Hide thumbs Also See for 3314A:
Table of Contents

Advertisement

Model 3314A
Performance Tests
UNIVERSAL
COUNTER
3314
4-3
Figure 4-3. Internal Trigger Accuracy
4-5, TRIANGLE LINEARITY
This procedure determines the linearity of the 3314A
Triangle wave at frequencies between 1Hz and 1kHz.
Specification:
+0.2%
Equipment Required:
High Speed Digital Voltmeter
50 Ohm Feedthrough Termination
Triax to BNC Connector
Procedures:
A. Preset the 3314A.
B. Set the 3314A as follows:
T'UncHOl-
erue ore
vite
e
eh
PK
IUS Triangle
Amplitude ..........................
10Vp-p
C. Set the Digital Voltmeter as follows:
Range tansa pakita
usu
u waa
qe nud
10V
ПОВЕС
ооа
RU Rae CP
PE
Ext
Reads;
өз
Сы
и
арена
SUN CE adeb oa
1
Delay
Сор
ELI LA
киы
ee ete кк
sm EE k 0.00055s
D. Connect the 3314A to the Voltmeter as shown in
Figure 4-4.
E. Note the Digital Voltmeter reading. Record this
value on the Performance Test Record under "Positive
Slope Measurement'.
This is the 10% point on the
positive slope of the Triangle (see Figure 4-5).
Е. Increment the delay on the Digital Voltmeter to
the values listed below. At each increment note and
record the corresponding voltage under ''Positive Slope
Measurement" in the Performance Test Record. (Each
increment
represents a 10%
segment
of the positive
slope.)
Delay
| Percent of Slope
0.00060
20
0.00065
30
0.00070
40
0.00075
50
0.00080
60
0.00085
70
0.00090
80
0.00095
90
G. Measurements
for the
negative
slope
of the
Triangle wave are made by incrementing the delay on
the voltmeter to the values listed below. Note and record
the
corresponding
voltages
under
''Negative
Slope
Measurement" in the Performance Test Record.
Delay
| Percent of Slope
0.00105
90
0.0011
80
0.00115
70
0.0012
60
0.00125
|
50
0.0013
40
0.00135
30
0.0014
20
0.00145
10

Advertisement