Download Print this page

Toshiba TC90101FG Manual page 25

Advertisement

 
 
BUS address 
19H:D7-D4  Threshold level at the 
phase difference big 
to middle 
19H:D3-D0  Threshold level at the 
phase difference middle 
to big 
1AH:D7-D5  Start phase for noise 
detection 
1AH:D4-D2  Width for noise  
detection 
1AH:D1-D0  The number of horizontal 
lines which Noise is 
detected in 
1BH:D7-D4  Start line for Noise  
detection 
1BH:D2 
HPLL-Lock-Gain 
1BH:D1-D0  fsc lock period 
1CH:D7-D4  Horizontal phase for  
digital format 
1CH:D3-D0  Vertical phase for  
digital format 
1DH:D7-D4  Start phase of  
Horizontal signal 
processing 
1DH:D3-D0  Width of Horizontal 
signal processing 
 
1EH:D7-D4  Start phase of vertical 
signal processing 
1EH:D3 
The  setup  of  the  vertical 
picture processing 
1EH:D2-D0  Setup of COMBKILL period  The period of COMBKILL is set up.  
1FH:D7-D4  Start phase of  
Horizontal BLK  
1FH:D3-D0  Width of Horizontal BLK  The width of H-BLANK-PULSE is set up. 
20H:D7-D4  Start  phase  of  burst  gate  The start phase of BURST-GATE-PULSE is set up. 
Feb./2005 
Function 
Threshold level that Phase-diffrent changes from Big to middle
is set up.  
Recommendation value: [0100] 
Threshold level that Phase-diffrent changes from middle to 
Big is set up.  
Recommendation value: [01000] 
The  horizontal-start-phase  of  the  detection  of  Noise  is  set  up.
"Point of 5.3µs from sync" is center. 
The horizontal-width of the detection of Noise is set up.  
The amount of noise-detection changes by Width. 
When width is widened, detection sensitivity rises. 
It is the numbers of lines which Noise is detected in. 
The number of line's can be set up from 1H to 4H. 
The vertical start line of the Noise detection is set up. 
60Hz:7-lines as 0H.It is set up in 1 line unit.  
50Hz:4-lines as 0H.It is set up in 1 line unit. 
The fsc Lock-Gain is set up.  
Usually used with 1/2.  
Lock-period of fsc is set up.  
Search-time becomes long, when it is set up 〜6V.  
But, it is easy to pull in. 
The position of EAV&SAV is set up.  
Usually, it uses with initial-value:0[us]. 
V-phase of VD is set up when "H/V OUT through". 
Variability of V-phase is the 1H unit. 
The  horizontal  start  phase  of  the  picture-processing-period  is
set up. The picture-processing is set up with COMBKILL 
(1EH D2〜D0). 
The horizontal width of the picture-processing-period is 
set up. The start reference is a horizontal start phase. 
Make adjustment after start-setup. 
The  vertical  start  line  of  the  picture-processing-period  is  set
up.It becomes MUTE to the setup from the vertical start line.
AUTO or MANUAL is selected. 
MANUAL  :  It  becomes  the  value  that  it  is  set  up  with  1EH(D7-D4).
AUTO: 60Hz= from 10th line / 50Hz= from 23th line 
Picture-processing is started from each line. 
This period doesn't do picture processing.  
AUTO:60Hz=1〜22H、50Hz=1〜23H 
But, it is a mask period to 21H by the Y/C input of 60Hz and 
the YCbCr input of 60Hz. 
The start phase of H-BLANK-PULSE is set up.  
Usually, it uses with initial-value:0[us]. 
Usually, it uses with initial-value:0[us]. 
 
 
Contents 
 
TC90101FG  
25 