Server - NEC Express5800 Series Maintenance Manual

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 2 Useful Features

1.2.4 Server

Server menu appears when the cursor is moved to Server. For the menu that has
to it and then press <Enter> key to show its submenus.
The Server menu screen shows the options you can configure and their features. For the menu System
Management, move the cursor to it and then press the <Enter> key to show its submenus.
Option
System Management
Power Control Configuration
Assert NMI on PCIe Error
FRB-2 Policy
Boot Monitoring
Boot Monitoring Policy
Thermal Sensor
Check previous System
Config
BMC IRQ
Parameter
Disabled
Enables or disables the NMI assert feature. A NMI is asserted
when a PCIe Uncorrectable error is detected and PCI PERR or
[Enabled]
SERR is detected.
[Retry 3 Times]
Specifies how the server should operate if FRB level 2 errors
occur.
Disable FRB2 Timer
Always Reset
[Disabled]
Enables or disables the boot monitoring feature and specifies
the timeout setting. To use this feature, install NEC ESMPRO
5-60 minutes
ServerAgentService on Windows. If starting up an OS on which
it is not installed, disable this feature.
[Retry 3 times]
Specifies the processing to be done when a time-out is enforced
during boot monitoring and the server is automatically reset.
Always Reset
Retry 3 times resets the server upon the timeout and attempts
to boot OS up to three times.
Always Reset retries booting the OS repeatedly.
This option can be selected only when Boot Monitoring is
enabled.
Disabled
Enables or disables the thermal sensor monitoring. If this option
is set to Enabled and when abnormal temperature is detected,
[Enabled]
the POST stops before starting an OS system stops at the end
of POST, and waits until the temperature becomes normal.
[Disabled]
If this option is set to Enabled and the system configuration
differs from the previous boot, the system waits for user's
Enabled
intervention before booting.
[Disabled]
Specifies whether to allocate interrupt lines for BMC.
IRQ 11
Express5800/B120f-h Maintenance Guide
on the left, move the cursor
Description
1. System BIOS
81

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/b120f-h exp437a

Table of Contents