Bosch Sensortec | BME280 User Manual
The following table lists some of the possible faults that you might encounter and the troubleshooting method.
Condition
If Communication Status remains
grey red after checking the Start
Button.
Unable to locate the data logged file.
Error message Please connect
application Board is displayed.
Error message Please connect
Shuttle Board is displayed.
Error message Please select a path
or file for logging is displayed.
Error message Please select File
from File Menu → Data Export
option to proceed is displayed.
Error message Please Connect
Valid Sensor is displayed.
Graph for x, y, z channel not plotted.
© Bosch Sensortec GmbH 2023 | All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution,
as well as in the event of applications for industrial property rights
Table 2 : General TroubeShoot
Possible cause
Application Board is turned off.
Destination path not properly defined. Locate the file in the setup path of
Application Board is not connected
properly.
Shuttle Board is not fixed properly.
Destination path for saving the
logged data is not defined.
Destination path not selected.
Wrong sensor fixed on the application
Board.
Channel x, y, z not checked.
Solution
Power on the application Board and
restart the DD2.1 UI application. If
the board is powered by
rechargeable battery, ensure that the
battery is charged.
Development Desktop.
Ensure that the PC is connected with
the application Board properly. If the
board is powered by rechargeable
battery, ensure that the battery is
charged.
Ensure that the Shuttle Board is
correctly fixed in the Development
Board.
Select the Data Export option in the
file menu and specify the destination
path.
In the file menu, select the Data
Export option and select the
destination path.
Ensure that correct sensor is fixed on
the application Board.
Ensure that x, y, z channels are
checked.
Document number: BST-BME280-DSxxx-yy
20 | 23