The fully automatic condensate drain (water separator),
the valve opens automatically as soon as the floater
is in the highest point. The valve closes
automatically when the floater reaches the
lowest point.
To set to automatic mode, turn the drain
screw fully to the right (left thread!).
Note: If the screw is installed completely, the
automatic drainage is blocked.
To drain the water separator manually
If the automatic water separator drain does not
respond and the condensate reaches the upper
mark (4), the condensate must be drained
manually.
1.
Turn the drain screw (5) fully to the left.
Setting pressure
1. Pull cap (6) upwards.
2. Turn the cap to set the pressure.
3. Press cap (6) down. The pressure regulator is now fixed.
Note: Never change the pressure settings unless you have explicit permission
from the Husqvarna technician.
The safety hooks must be completely retracted if reset the pressure.