6.5. The overview of the VF-S15/AS3/MB1 parameter

6.5.1.
fa06 (Communication command1) (VF-S15/MB1)
bit
Function
Preset speed operation
0
frequencies 1
Preset speed operation
1
frequencies 2
Preset speed operation
2
frequencies 3
Preset speed operation
3
frequencies 4
Motor selection (1 or 2)
4
(THR 2 selection)
5
PI D control
Acceleration/decele-
ration pattern selection
6
(1 or 2)
(AD2 selection)
7
DC braking
8
Jog run
Forward/reverse run
9
selection
10
Run/stop
11
Coast stop command
12
Emergency stop
13
Fault reset
Frequency priority
14
selection
Command priority
15
selection
* When 14(sr0) is set to fmod, preset speed operation frequency 0 is selected.
0
1
Preset speed operation is disabled
or preset speed operation
frequencies (1-15) are set by
specifying bits for preset speed
operation frequencies 1-4.
(0000: Preset speed operation OFF*,
001-1111: Setting of preset speed
operation frequencies (1-15)
Motor 1
Motor 2
(THR 1)
(THR 2)
Normal operation
PI D off
Acceleration/dec
Acceleration/decel
eleration pattern
eration pattern 1
2
(AD1)
(AD2)
Forced DC
OFF
braking
OFF
Jog run
Forward run
Reverse run
Stop
Run
Standby
Cost stop
OFF
Emergency stop
OFF
Reset
OFF
Enabled
OFF
Enabled
- 38 -
E6582051
Note
THR 1: pt = setting value,
vl, vlv, vb, thr
THR 2: pt = 0, f170, f171,
f172, f173
-
AD1: acc, dec
AD2: f500, f501
-
-
-
-
-
Always enable, "E" trip
No data is returned from the drive
Enabled regardless of the setting
of fmod
Enabled regardless of the setting
of cmod