DATA PROGRAMMING
Assignment of FCH Related Data
STEP 4: ACAN
Assign the Fusion Connection Index Code (FCIC) and the LENs on an adjacent FPC basis.
34
shows a sample data sheet for Node A.
It is not necessary to assign the same number as trunk and FCIC. However, FCIC numbers between adja-
Note:
cent nodes must be identical.
A sample data sheet at Node A is as follows.
FPC = 2
FCIC = 1
FPC = 2
FCIC = 2
FPC = 2
FCIC = 3
FPC = 2
FCIC = 4
:
:
The ACAN command display should look similar to the following:
For Help, press F1
CHAPTER 5
Page 86
Revision 3.0
LCN
NCN
C_LENS = 000010
C_LENS = 000011
C_LENS = 000012
C_LENS = 000013
:
LCN
Figure 5-34 ACAN Sample Data Sheet
ACAN (Assignment of CIC Number between Adjacent Node for Network)
Assign Adjacent FPC
FPC
FCIC
Fusion Circuit Identification Code
2
1
C_LENS
000011
WRT?
Figure 5-35 ACAN Command Display (example)
ND-70185 (E)
Get other manuals https://www.bkmanuals.com
LCN
Node A
TRK 1
FCIC=1
TRK 3
1
FCIC=2
:
:
FCIC=n
TRK 10
C_RT=10
Self-Node
FCIC number must be identical
C_LENS
Figure 5-
LCN
Node B
LCN
TRK 31
FCIC=1
TRK 32
FCIC=2
2
:
:
FCIC=n
TRK 40
Adjacent-Node
LCN