Table of contents Table of contents 10 Display of consumption values in relation to the funding guidelines for federal funding for efficient buildings - individual measures (BEG EM) ....18 Explanation of symbols and safety instructions .
Explanation of symbols and safety instructions HSafety of electrical devices for domestic use and similar Explanation of symbols and safety instructions purposes The following requirements apply in accordance with EN 60335-1 in Explanation of symbols order to prevent hazards from occurring when using electrical appliances: Warnings “This appliance can be used by children of 8 years and older, as well as...
Product Information 2.1.2 Protection zone, ground-placed heat pump free standing or Product Information on a flat roof Heat pump AW OR together with the Pre plumbed cylinder indoor unit is part of a series of heating systems that use outdoor air to provide energy for water transferred heat and domestic hot water.
Product Information Heat pump (outdoor unit) T0[°C] The heat pump is inverter operated, which means that it will automatically change the compressor speed to deliver the exact amount of energy required at the moment. The fan is also RPM controlled and will change its speed as needed.
0010049120-001 Fig. 6 Heat pump AW OR, indoor unit Pre plumber cylinder CS5800iAW 180 MCP with integrated domestic hot water cylinder and immersion heater Hints on energy saving Control unit •...
Page 7
Product Information In the manual the displays are shown from left to right. The display shown as the start screen in the heat pump depends on which settings have been selected and which accessories are installed. 0010042067-002 Fig. 9 Control Panel Present: Direct access to settings for presence/absence.
Operation The system overview shows the status of the heat pump and Operation temperatures in the system and surroundings. WARNING Material damage from frost! The heating or auxiliary heater may be irreparably damaged by frost. ▶ Do not start the heat pump if there is a possibility of the heating or auxiliary heater being frozen.
Main menu Menu > Hot water Menu item Description Season switch In the summer, the heating mode can be switched Menu item Description off for the selected heating circuit. The DHW mode is Set operating ▶ Select Off to switch off DHW production. not affected by this setting.
Main menu Menu > Holiday Menu item Description Solar sensor ▶ Shows the system sensors Menu item Description overview Holiday ▶ From. Set the start date/time for absence: the Solar yield ▶ Shows statistics on energy produced holiday program starts at the set date/time. overview Select Confirm to confirm or Cancel to return without making changes.
Main menu Settings Menu item Description Menu > Press menu button in the Start menu at the top on the left to call Standby mode The heat pump is normally switched on. The system up the "General settings" menu. is only switched off in order to carry out maintenance or similar tasks.
2 bar. Personal injuries may occur. ▶ Contact your installer or Worcester Bosch technical help line, if you ▶ Disconnect the power supply before carrying out maintenance work. require assistance with increasing the pressure.
Maintenance ▶ Screw the cap back on (tighten handtight). ▶ Open the valve (4). In some regions, the cleaning agent must not be flushed into gravel beds. Check and clean the particle filter annually. If the condensate tube discharges into a gravel bed: Check and clean the magnetite filter (if fitted) ▶...
You can contact our Data Protection Officer under: where you purchased the product. Data Protection Officer, Information Security and Privacy (C/ISP), Robert Bosch GmbH, Postfach 30 02 20, 70442 Stuttgart, GERMANY. You can find more information here: www.weee.bosch-thermotechnology.com/...
Open Source Software Appendix - License Text 3. Grant of Patent License. Subject to the terms and conditions of this License, each Contributor 9.2.1 Apache License 2.0 hereby grants to You a perpetual, worldwide, non-exclusive, no-charge, Apache License Version 2.0, January 2004 royalty-free, irrevocable (except as stated in this section) patent license http://www.apache.org/licenses/ to make, have made, use, offer to sell, sell, import, and otherwise...
Open Source Software warranties or conditions of TITLE, NON-INFRINGEMENT, 9.2.3 License for STM32CubeMX (STMicroelectronics) MERCHANTABILITY, or FITNESS FOR A PARTICULAR PURPOSE. You are Redistribution and use in source and binary forms, with or without solely responsible for determining the appropriateness of using or modification, are permitted, provided that the following conditions are redistributing the Work and assume any risks associated with Your met:...
Display of consumption values in relation to the funding guidelines for federal funding for efficient buildings - individual meas- The DHW or heating mode can be prioritised by selecting an option on Display of consumption values in relation to the the control unit.
Overview Menu Inverter Hot water cylinder Located in the outdoor unit and enables the speed of the compressor to A DHW cylinder stores large volumes of heated potable water. Sufficient be controlled based on the heat energy demand in each case. hot water is available at the draw-off points (e.g.
Page 20
Overview Menu – Desired room temp. heating Solar – Cooling – Cooling mode HC1 – Solar sensor overview – Desired room temp. cooling – Solar yield overview – Cooling on from – Rename heating circuit Holiday Hot water – From –...