Gas Connection - Miele PRI318 G Installations Plan

Commercial ironer (gas heating)
Table of Contents

Advertisement

The required voltage, rated load and external fuse rating can be found on the data plate
on the flatwork ironer.
Connection to a supply voltage other than the one quoted on the data plate can lead to
functional faults and damage to the flatwork ironer.
Before connecting the flatwork ironer to the electricity supply, please ensure that the
mains supply voltage complies with the values given on the data plate.
The electrical equipment of the flatwork ironer complies with standards IEC 61000-3-12,
IEC/EN 60335-1, IEC/EN 60335-2-44, EN ISO 10472-1 and EN ISO 10472-5.
For ease of servicing and maintenance the ironer should be installed with a suitably rated
plug and socket.
In the case of unfavourable electrical conditions, the flatwork ironer may lead to interfering
voltage fluctuations. If the mains impedance is greater than 0.265 ohm at the connection
point to the public mains network, additional measures may be required before the appli-
ance can be properly operated using this connection. The mains impedance can be re-
quested from the local power supply company if necessary.
The plug connector or isolator switch should be easily accessible at all times.
If the flatwork ironer is disconnected from the electricity supply, the disconnector must be
lockable or the point of disconnection must be monitored at all times.
If it is necessary to install a residual current device (RCD) in accordance with the local reg-
ulations, a type-A residual current device can be used.
If the machine is hard wired, an all-pole means of deactivation must be installed. Switches
with a minimum contact gap greater than 3 mm are suitable disconnectors. These include
circuit breakers, fuses and contactors (VDE 0660).

Gas connection

The gas connection may only be carried out by a registered installation technician in ac-
cordance with the applicable national regulations. In addition, the regulations of the local
gas supply company must be observed.
Service work on gas appliances may only be carried out by suitably qualified persons in
accordance with all applicable safety regulations. Before any service work is com-
menced on the appliance, the machine must immediately be disconnected from the gas
mains.
Follow the installation instructions for the gas connection.
The gas heating is set as standard in accordance with the ironer's gas rating (see the data
plate on the rear of the machine).
If the gas type needs to be changed, please request the appropriate conversion kit from
the Miele Customer Service Department. When doing so, please have ready the informa-
tion on the type of ironer, the appliance number, gas type, gas group, gas connection pres-
sure and country in which the appliance is installed.
Installation notes