Elevator/Escalator Mode; Segment Indication Of The Elevator - Hitachi EC2-605 Instruction Manual

Table of Contents

Advertisement

 
  4. Elevator/Escalator Mode
When the power is ON by setting the functional selector switch to other than Group/Door mode according to
Section 3 How to Turn the Power ON, the display will indicate the operation state of the elevator/escalator.
This section describes the operation state indication. Please don't use the console other than EC4-605 for
the escalator.

4.1 Segment Indication of the Elevator

When indicating the operating state of the elevator, the 9-digit segment sections indicate trouble code and
the position of the elevator car. This section describes the contents of the segment indication. For
escalator, read Section 4.3 and onward.
(8th and 9th digits):
Trouble Section
Table of the contents of operating state indicated in the segment sections of the display (Elevator)
Item
(6th digit):
Direction of
operation
Upward
(4th and 5th
digits): Position
of the elevator
car
In the case of 12 floor operation
without the basement floor
(3rd digit):
Trouble section 2
Operation control Speed control
system (Master
Microcomputer)
(8th, 9th, 1st and
2nd digits):
Trouble section
and trouble code
Trouble section   Trouble code
 
 
(6th digit):
Direction of
operation
Segment indication
Downward
system (Slave
Microcomputer)
(4th and 5th
(3rd digit):
digits):
Trouble
Position of the
Section 2
elevator car 
Descriptions
Indicates that the direction of operation is in two ways,
upward and downward.
Indicates the floor the car is positioned at. Irrespective
of the presence of the basement floor, the indicator
always indicates the lowest floor as 1. (Example: For a
building having the basement floor, 6th floor of the
building is indicated as
Operating system: Failure detected in the operation
control system Speed system: Failure detected in the
speed control system Indicates the section of trouble
code when abnormality occurs. (Refer to the
Attachment: List of Table of Trouble Codes)
Indicates the section and code of the trouble in the
operation or speed control system. If trouble should
occur simultaneously to both the operation and speed
control systems, indication appears alternately. The
7th digit is for the escalator and not concerned with the
elevator. (Refer to the Attachment: List of Trouble
Codes)
(1st and 2nd
digits):
Trouble code
.)
16