NEC EXP803 Maintenance Manual page 198

Express server
Hide thumbs Also See for EXP803:
Table of Contents

Advertisement

Chapter 3 Appendix
l2nd
4
When installing an OS, starting system,
or applying Starter Pack
Megasas
11
When applying Starter Pack
mlx4_bus
24
When starting system with
N8104-146/147 (InfiniBand card)
connected
ixgbt
27
When starting system, or applying
Starter
ixgbi
27
When installing an OS
volmgr
46
When installing an OS
Microsoft-Windows-Time-S
ervice
134
When installing an OS, starting system,
or applying Starter Pack
disk
153
When creating logical drive by Universal
RAID Utility
198
Broadcom BCM57810 #xx: The network link is down.
Warning
Check to make sure the network cable is properly connected.
This event does not affect system operation.
Error
The driver detected a controller error on \Device\RaidPort(x).
This event does not affect system operation if it is logged when applying
Starter Pack.
MLX4_SF_32_0_0:
Problem - The port was configured to use auto sensing for deciding the
port type. Port * failed to detect the port type automatically.
Impact - As a result the port is being started as an IB port (unless the
port is ETH only). This may cause a connection problem if the other side
Warning
is an ETH port.
Reason and suggestion to fix - This problem may happen since the
computer is connected back to back or the cable is unplugged.
To solve this issue connect the port to a switch or define the port type
explicitly (IB or ETH) instead of auto.
If Auto Negotiation fails in InfiniBand connection environment (e.g.,
InfiniBand cable is not connected), the port works as IB port. Thus, this
event does not affect system operation.
Intel(R) Ethernet Controller X540-AT2 #xx
Warning
Network link is disconnected.
This event does not affect system operation.
Intel(R) Ethernet Controller X540-AT2 #xx
Warning
Network link is disconnected.
This event does not affect system operation.
Error
Crash dump initialization failed!
Go to the following Microsoft website for details.
http://support.microsoft.com/kb/2756313
NtpClient was unable to set a manual peer to use as a time source
Warning
because of a DNS resolution error on 'time.windows.com,0x9'. NtpClient
will try again in 15 minutes and double the reattempt interval thereafter.
If it is not registered after connecting to the Internet, there is no problem
with system operation.
The I/O operation at the logical block address for disk was retried.
The on-screen indication may differ depending on system
Warning
environment.
The character string of this event may not be displayed correctly,
however, it does not affect the system operation.
If this event is logged when creating a logical drive by Universal RAID
Utility, there is no problem in system operation.
The character string of the event will be correctly displayed by applying
the Microsoft's update program on the following site:
http://support.microsoft.com/kb/2925479
Express5800/R120f-1E Maintenance Guide
2. List of Windows Event Logs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r120f-1eExpress5800 series

Table of Contents