NEC EXP803 Maintenance Manual page 187

Express server
Hide thumbs Also See for EXP803:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C068
8th SMBus device Error
detected.
C101
BMC Memory Test
Failed.
C102
BMC Firmware Code
Area CRC check Failed.
C103
BMC core hardware failure.
C104
BMC IBF or OBF check failed.
C105
BMC SEL area full.
Cause
An error was detected on 1st SM
Bus.
An error was detected on 2nd SM
Bus.
An error was detected on 3rd SM
Bus.
An error was detected on 4th SM
Bus.
An error was detected on 5th SM
Bus.
An error was detected on 6th SM
Bus.
An error was detected on 7th SM
Bus.
An error was detected on 8th SM
Bus.
An error was detected on BMC.
An error was detected while
accessing BMC.
There is not enough space to store
the system event log.
Express5800/R120f-1E Maintenance Guide
1. POST Error Message
Solution
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Run Offline Tools (Chapter 1, 9. Offline Tools)
and clear the event logs.
187

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/r120f-1eExpress5800 series

Table of Contents