GE 750 UL S2 User Manual page 32

Table of Contents

Advertisement

Code
4570
OVERLOAD
4571
OVERLOAD: LOAD ON UTILITY
INVERTER AND UTILITY NOT
4581
SYNCHRONIZED
4608
ECO CONFIG FAILURE
MAIN BOARD BATTERY CHANGE
4681
4682
DC CAPACITORS CHANGE NEEDED
4683
AC CAPACITORS CHANGE NEEDED
4684
FAN REPLACEMENT NEEDED
4685
SERVICE MAINTENANCE OVERDUE
4697
BATTERY OVERTEMPERATURE
4698
BATTERY POWER INSUFFICIENT
4700
POWER SUPPLY BOARD
4701
4900
LOAD LOCKED ON INVERTER
4955
OVERTEMPERATURE
LOAD OFF DUE TO EXTENTED
4998
OVERLOAD
LOAD OFF DUE
4999
TO LOW BATT. OR TEMP.
Modifications reserved
OPM_SGS_USM_M75_M75_2US_V010.doc
Alarms
NEEDED
DC LOW
FAILURE
The UPS-System is in an overload condition >125% on
Inverter, or >150% on Utility.
With Utility unavailable, a sequence of "stop operation"
starts.
Time out depends on Load quantity.
With Utility Bypass supply available and load >115%,
the Load is transferred on Utility.
Load will be transferred again automatically on Inverter
when Load <100%.
The
voltages
of
Utility
synchronized, which causes the opening of K6.
The propagation of the eBoost / IEMi configuration to
other units in a Parallel System failed.
Notice to replace the Lithium Battery located on the P3
- IM0007 Control Board.
Notice to replace the DC Capacitors.
Notice to replace the AC Capacitors.
Notice to replace the Fans.
Notice to do the Service Maintenance.
Detection of Battery over temperature condition.
Can be deactivated by Service Center.
In case of Utility Failure, with the actual Load, the run
time would be below stop operation time (default 3
minutes).
Battery voltage is at the lowest limit.
Will stay Off Inverter until the battery voltage reaches
the value in parameter.
Failure detection on the +24V derived from the DC-link
voltage.
The Load is locked on Inverter after 3 Load transfers
within 30 seconds.
After time out (default 30 seconds) Bypass will be free.
An over-temperature condition has been detected on
Inverter.
Elapsed "stop operation" time, Inverter shutdown.
With Utility OK, Load is transferred on Utility.
Load Off after time-out of "stop operation" for overload
on Inverter or Bypass (time depending on the % of
overload).
Load Off after time-out of "stop operation" with missing
Utility due to Battery low voltage or over-temperature
condition.
Meaning
and
Inverter
User Manual SG Series 750 UL S2 & SG Series 750 T12 UL S2
are
not
Page 32/71