(3) Check to confirm the lens value specified on the lens value
label.
(4) Insert a screwdriver into hole (P) in the right rear side (paper
feed side) of the optical base plate, and adjust the adjustment
screw. The scale on the zoom base at section Q in the figure
below determines the position of the No. 4/5 mirror cor-
responding to the lens value.
<Example> When the lens value is +1.2, loosen the adjustment
screw and adjust so that the arrow section of the No.
4/5 mirror drive holder points to the zoom base scale at
+1.2.
Turning the adjustment screw clockwise moves the No.
4/5 mirror drive holer arrow section in the (–) direction,
and turning it counterclockwise moves the arrow sec-
tion in the (+) direction.
C. Vertical copy magnification ratio adjustment
Be sure to check that mirror bases A, B and C are in parallel and
that the focus is proper before executing this adjustment.
This adjustment must be performed in the following cases.
When the lens home position sensor (LHPS) is replaced or its
installation position is changed.
When the lens is replaced.
When the mirror base is replaced or its installing position is
changed.
When the main PWB is replaced.
When the EEPROM inside the main PWB is replaced.
(When a 100mm scale is used as the original.)
Paper feed direction
mm
10
20
100
1/2mm
mm
10
20
100
1/2mm
Reference
Comparison point
7 – 5
No. 4/5 mirror drive
holder arrow section
Zoom
One scale = 1mm
base
(-) direction (+) direction
<Procedure>
(1) Put a scale on the original table as shown in the figure below.
Scale
(2) Make a normal copy (100%) on an A4 (11" ×8
(3) Compare the scale image length and the scale length.
JAPAN
110
120
130
140
JAPAN
110
120
130
140
110
No.4/5 sdjustment
screw
(shaded portion)
Q
A4 (11" x 8½")
paper
1
") paper.
2
Original scale
HARDDENCD
STAINLESS
150
Shizuoka
HARDDENCD
STAINLESS
150
Shizuoka
Copy
P