Download Print this page

Sharp 00ZSF1116/A1E Service Manual page 101

Advertisement

Main code
Sub code
51
02
Resist amount adjustment
Used to set the warp amount of paper in the resist section.
When this simulation is executed, warm-up is started and the currently set tray resist amount is displayed on the
copy quantity display.
After completion of warm-up, the ready lamp is lighted. Press the PRINT button to start copying.
Since there are two or more display items, the third digit is used to make distinction between the light reception
level and the original judgment level, and the lower two digits are used to display the data.
The display is selected by the magnification ratio key.
The details of the adjustment are as follows.
This adjustment is used to set the time (resist amount) from the paper transport sensor (PPD) ON to paper feed
operation OFF. The set range is 1 ∼ 99.
Set value × 1 msec + 70 msec = Resist amount
For WLT, A3, LG, B4, foolscap, LTR, or A4R, however, +15 is added to the simulation set value by the software.
(Example) When the simulation set value is 40, +15 is added to 40 by the software and the actual value is 55.
53
01
ADF (single) stop position setting
Used to set the original stop position in ADF (single) transport.
When this simulation is executed, the currently set stop position data is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Setting range: 0 ∼ 15
04
ADF resist sensor adjustment
Used to adjust the ADF resist sensor original judgement level.
When this simulation is executed, the resist sensor original judgement level is adjusted. After completion of
adjustment, the original judgement level is displayed on the copy quantity display.
Display range: 0 ∼ FFh (hexadecimal)
06
ADF timing sensor adjustment
When this simulation is executed, the paper exit reverse sensor original judgement level is adjusted. After
completion of this adjustment, the original judgement level is displayed on the copy quantity display.
Display range: 0 ∼ FFh (hexadecimal)
54
03
Sorter buzzer setting
Used to adjust the sound volume of the sorter removal buzzer and the staple warning buzzer.
(When the SF-S54 is installed)
(When the SF-S17N is installed)
Copy quantity display
3rd digit
2nd, 1st digits
1 ∼ 99
A
b
A ... Cassette (Initial set value 40)
B ... Manual feed
Set value
Buzzer setting
0
Volume Large
1
Volume Middle
2
Volume Small
3
OFF
Set value
Buzzer setting
0
ON
3
OFF
Content
Display data
Tray resist amount
Manual feed resist amount
← Initial setting
← Initial setting
8 – 15
← Initial set value: 45
← Initial set value: 50