Advertisement

Quick Links

Installation Instructions
Tumble Dryer
PT 825x
PT 830x SL
PT 833x
PT 840x
PT 850x
PT 880x
To prevent accidents and machine damage, read
en-US
these instructions before installation or use.
M.-Nr. 07 713 843

Advertisement

Table of Contents
loading

Summary of Contents for Miele PT 825 Series

  • Page 1 Installation Instructions Tumble Dryer PT 825x PT 830x SL PT 833x PT 840x PT 850x PT 880x To prevent accidents and machine damage, read en-US these instructions before installation or use. M.-Nr. 07 713 843...
  • Page 3: Table Of Contents

    IMPORTANT SAFETY INSTRUCTIONS ................ 4 Supply air, exhaust, and ventilation cross-sections............ 5 Calculating the total length and diameter of a supply-air or exhaust pipe ......5 Muffler (Miele accessory available to order)................5 Substitute pipe lengths ......................6 Maximum permissible total pipe length ................6 Room ventilation opening for air intake from the setup room..........
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS This appliance must be installed by a qualified technician in compliance with local regu- lations and standards and may only be operated in an adequately ventilated room. Read the installation instructions and operating instructions before installing and operat- ing the appliance.
  • Page 5: Supply Air, Exhaust, And Ventilation Cross-Sections

    The on-site exhaust ducting and venting to the outdoors must be regularly checked for lint deposits and cleaned if necessary. Muffler (Miele accessory available to order) The use of mufflers for exhaust ducting used with gas-heated washing machines or ironers is not permitted.
  • Page 6: Substitute Pipe Lengths

    Table 2 If the total pipe length exceeds the length specified in Table 2, contact Miele ProService. When connected to the ducting through the exhaust nozzle of an appliance, particular care must be taken to make sure the connection is secure and air-tight.
  • Page 7: Room Ventilation Opening For Air Intake From The Setup Room

    Supply air, exhaust, and ventilation cross-sections Due to the higher air flow rates, the exhaust ducting must be laid in such a way that air flow is not hindered (few bends, short pipelines, well-made connections and transitions checked for air-tightness). No filters or louvres may be fitted in the exhaust ducting. The end of ducting leading into the open should be protected against the elements, e.g., with a downward facing 90°...
  • Page 8: Exhaust Connection

    Supply air, exhaust, and ventilation cross-sections 13/16" (20 mm) >35 7/16" (900 mm) 2 1/16" (52 mm) Exhaust connection 1 7/16" (37 mm)
  • Page 9: Example 1

    Supply air, exhaust, and ventilation cross-sections Example 1 Configuring exhaust ducting made from steel for the PT 825x series tumble dryer: L1, L2: each 9' 10" (3 m) steel piping B1, B2: each 90° concertina pipe elbow (r = 2d) 90° elbow (r = d) 1. Total pipe length Steel pipe L1 = 9' 10" (3.0 m) Steel pipe...
  • Page 10: Example 2

    Supply air, exhaust, and ventilation cross-sections Example 2 Common combined exhaust ducting for multiple appliances should only be considered as a solution in exceptional cases. Configuring combined exhaust ducting made from steel for the PT 825x and PT 833x se- ries tumble dryers: L1–L4 each 6' 6" (2 m) steel piping B1–B3...
  • Page 11 Supply air, exhaust, and ventilation cross-sections 1. Total pipe length, PT 825x Steel pipe L1 = 6' 6" (2.0 m) Steel pipe L2 = 6' 6" (2.0 m) Steel pipe L4 = 6' 6" (2.0 m) 90° concertina pipe elbow B1 = 10' 6" (3.2 m)* (r = 2d) 90° concertina pipe elbow B2 = 10' 6" (3.2 m)* (r = 2d) 90° elbow (r = d) B3 = 6' 3" (1.9 m*)
  • Page 12: Example 3

    Supply air, exhaust, and ventilation cross-sections Example 3 Configuring exhaust ducting and a supply pipe made from steel for the PT 825x series tumble dryer: L1, L2: each 6' 6" (2.0 m) steel piping 8' 2" (2.5 m) steel piping B1, B2: 90° concertina pipe elbow for each B3, B4: 90° elbow (r = d) for each 1. Total pipe length...
  • Page 13: Configuring The Room Ventilation Opening

    Supply air, exhaust, and ventilation cross-sections Configuring the room ventilation opening  Rooms in which flatwork ironers and tumble dryers are operated must have an in- duced ventilation system (ventilation slots in windows and doors, wall breakthroughs with louvres or opened windows or skylights). For example 1 A pipe diameter of 6" (150 mm) was specified.
  • Page 14: Gas

    Take these safety precautions if you smell gas – Extinguish all flames immediately. – Open all windows and doors immediately. – Close the gas shut-off device on the gas meter or the main gas shut-off device immedi- ately. – If there is the smell of gas in a room, never enter the room with a naked flame. –...
  • Page 15: Gas Supply

     Before completing commissioning, maintenance, conversion, and repair work, all gas-conducting components – from the manual shut-off valve to the burner jet – must be checked for leaks. Particular attention must be paid to the measuring stubs on the gas valve. Checks must be performed when the burner is both switched on and switched off.
  • Page 16 Propane (LP) Propane (LP) Length of gas line 15" (5 m) 32' 9 11/16" (10 m) 65' 7 3/8" (20 m) 164' 1/2" (50 m) Internal Maximum flow rate diameter 3/8" (10 mm) 1.3 kg/h 1.0 kg/h 1/2" (12 mm) 2.0 kg/h 1.5 kg/h 1.0 kg/h...
  • Page 17: What Needs To Be Observed During Commissioning

    If the gas family needs to be changed, please request the appropriate conversion kit from Miele Service. When doing so, please specify the product name and the appli- ance number, as well as the gas family, gas group, gas connection pressure, and country where the appliance has been set up.
  • Page 18 Main connection PT 830x SL Natural gas Liquid gas Hose Threaded union Reducing nipple Hose Gas regulator valve PT 830x SL Jet pressure measuring stub Connection pressure measuring stub Adjusting screw Head screw Spring Jet pressure adjustment Unscrew the head screw.  Adjust the jet pressure with the adjusting screw (see Table 6 for natural gas and Table 7 ...
  • Page 19  Gas lines and screw connections may leak after connection and conversion work. Gas may escape. After connection and conversion work, the gas lines, all screw connections (including those on the jets), and the locking bolts on the measuring stubs must be checked to en- sure they are leak-tight.
  • Page 20 Gas regulator valve PT 825x, PT 833x, PT 840x, PT 850x, PT 880x Special tool Jet pressure measuring stub Pressure regulator Connection pressure measuring stub Screw Plug Jet pressure adjustment Only the special tool may be used for adjustment via the pressure regulator. Loosen the locking bolts of the connection pressure and jet pressure measuring stub. ...
  • Page 21 To increase the minimum jet pressure, turn the top ring on the special tool in a clockwise  direction. The screw of the pressure regulator is tightened by the special tool. To reduce the minimum jet pressure, turn the top ring on the special tool in a counter- ...
  • Page 22: Settings With Natural Gas

    Burner conversion Replace the jet and the sealing ring (included with the conversion kit).  – Natural gas = large hole – Liquid gas = small hole Additional steps necessary to convert to liquid gas are outlined in the “Conversion kit for natural gas to liquid gas conversion”.
  • Page 23: Steam

    In addition to these installation instructions, the information from the data plate, wiring diagram, and documentation accompanying the appliance must also be noted and com- plied with when connecting steam-heated Miele appliances. Miele steam-heated appliances are not subject to testing in accordance with EC Directive 97/23/EC for pressure equipment. Operating pressure values High-pressure steam version, indirect HP indir.
  • Page 24: Steam Valve For High-Pressure Steam - Indirect

    Steam Steam valve for high-pressure steam – indirect Requirements profile: – Pneumatic or servo-controlled – Connection to ½" coupling – Flow coefficient of at least 3 m³/h for water – Media temperature at least 365°F (185°C) – Operating voltage 230 V / 50–60 Hz –...
  • Page 25: Hot Water

    In addition to these installation instructions, the information from the data plate, wiring diagram, and documentation accompanying the appliance must also be noted and com- plied with when connecting hot water-heated Miele appliances. Operating conditions Operating pressure Feed water temperature Peak capacity 87-145 psi / 600–1,000 kPa (6–10 bar)
  • Page 26 Technical Service & Support Phone: 800-991-9380 Miele Professional Fax: 800-220-1348 Technical Service proservice@mieleusa.com Phone: 1-888-325-3957 Fax: 1-800-803-3366 serviceprofessional@miele.ca Germany Manufacturer Miele & Cie. KG Carl-Miele-Straße 29 33332 Gütersloh Alteration rights reserved / Publication date: 49.19 M.-Nr. 07 713 843 / 00...