D-Link DCS-80-5 Quick Installation Manual page 11

Outdoor power box
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Figura 2. Diagrama de Tablero de alarma
10 (J2)
Pin
Definición
ALR_COM
ALARMA
COM
ALR_NC
Cerrar
ALARMA
Normal
ALR_NO
Abrir
ALARMA
Normal
ALR_GND
ALARMA
GND
ALARM 8
ALARMA
PIN 8
ALARM 7
ALARM
PIN 7
Tabla 3. Definición de Pin de Tablero de alarma
11 (J3)
Pin
Definición
ALARMA 6
ALARMA
PIN 6
ALARMA 5
ALARMA
PIN 5
ALARMA 4
ALARMA
PIN 4
ALARMA 3
ALARMA
PIN 3
ALARMA 2
ALARMA
PIN 2
ALARMA 1
ALARMA
PIN 1
Tabla 4. Definición de Pin de Tablero de alarma
8 (J1)
Pin
Definición
ALR_COM
ALARMA
COM
ALR_NC
Cerrar
ALARMA
Normal
ALR_NO
Abrir
ALARMA
Normal
ALR_GND
ALARMA
GND
ALARM 8
ALARMA
PIN 8
ALARM 7
ALARMA
PIN 7
9 (J4)
Pin
Definición
ALARMA 6
ALARMA
PIN 6
ALARMA 5
ALARMA
PIN 5
ALARMA 4
ALARMA
PIN 4
ALARMA 3
ALARMA
PIN 3
ALARMA 2
ALARMA
PIN 2
ALARMA 1
ALARMA
PIN 1
C1 C2 C3 C4
PUERTO
Diámetro cable
C1, C3
6 mm - 12 mm
C2, C4
10 mm - 14 mm
Tabla 5. Diagrama Interno
Nota de Conexión
- Conecte todos los dispositivos antes de
enchufar la fuente de alimentación.
- Verifique que el modelo de caja de
alimentación cumple con los requisitos de
voltaje de su dispositivo.
Preparación Antes de la Instalación
Prepare la caja de alimentación para la
instalación:
- Quite los tornillos de la tapa de la caja de
alimentación.
- Retire la tapa y déjela a un lado.
- Elimine el relleno de la caja.
- Consulte el diagrama de caja de alimentación
en este manual, cuando conecte los cables
de datos y de alimentación.
- Consulte el diagrama de tablero de alarma
para conectar el cableado de alarma si es
necesario.
- Especifique el voltaje apropiado del
adaptador.
D-Link DCS-80-5/6 Outdoor Power Box  11
Propósito
Para cable de
alimentación
(AC 110 V/220 V
o AC 24 V)
Para cámara Domo
o Cable de datos
externo