400V 3N~ Indoor Unit With 230V~ Outdoor Unit - Bosch Compress 3400i AWS Installation Manual

Indoor unit for air to water heat pump
Hide thumbs Also See for Compress 3400i AWS:
Table of Contents

Advertisement

11.4.5 400V 3N~ indoor unit with 230V~ outdoor unit

3
2
1
Fig. 39 400V 3N~Indoor unit with 230V~ outdoor unit
[1]
Indoor unit terminals
[2]
EMS module (accessory)
[3]
Overheating protection
[4]
Electrical heater (3x1,95kW)
[5]
Installer module power supply
[6]
Pressure switch
[7]
CAN bus line
[8]
Outdoor unit
[9]
Outdoor unit terminals
[10] 230V ~ power supply from the distribution board to the outdoor
unit
The output of the electric booster heater must be limited to a maximum
of 3.9kW with the configuration in parallel mode with the outdoor unit.
• Electric booster heater in compressor mode: 1.95-3.9kW (K3
blocked)
• Only electric booster heater, compressor off: 1.95-3.9-5.85kW
Compress 3400i AWS – 6721852066 (2023/01)
4
5
8
9
CAN
CAN
CAN
GND
L
H
10
Technical information
6
7
N
L
0010036907-004
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs3400iaws 10 e

Table of Contents