  • Page 1 Models: CRNN-SP Series Type: Art Cool IMPORTANT • Please read this installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. • Please retain this installation manual for future reference after reading it thoroughly.
  • Page 2: Table Of Contents

    Art Cool Type Indoor Unit Installation Manual TABLE OF CONTENTS Installation Requirements Required Parts Required Tools Installation Parts ....3 Safety Precautions ....4 Installation Installation guide map Level gauge Four type "A" screws & plastic Screw driver anchors Electric drill Selection the best location ..7 Connecting cable Hole core drill Horizontal meter...
  • Page 3: Installation Parts

    Installation Parts Installation Parts Intake Air Outlet Securing screws Name Installation guide map (Other) Quantity 1 EA 2 EA • Owner's manual Shape • Installation manual M4 x 12L Installation Manual 3...
  • Page 4: Safety Precautions

    Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Be sure to read before installing the air conditioner. Be sure to observe the cautions specified here as they include important items related to safety. Incorrect operation due to ignoring instruction will cause harm or damage.
  • Page 5 Safety Precautions Do not modify or extend the Do not let the air conditioner Be cautious when unpacking power cable. run for a long time when the and installing the product. humidity is very high and a door or a window is left open. •...
  • Page 6 Safety Precautions Installation Always check for gas (refriger- Install the drain hose to ensure Keep level even when installing ant) leakage after installation or that water is drained away prop- the product. repair of product. erly. • Low refrigerant levels may cause •...
  • Page 7: Installation

    Installation Installation Read completely, then follow step by step. Selection of the best location • Do not have any heat or steam near the unit. • Select a place where there are no obstacles in front of the unit. • Make sure that condensation drainage can be conveniently routed away. Do not install near a doorway.
  • Page 8: Preparing Work For Installation

    Installation Preparing Work for Installation The wall you select should be strong and solid enough 2) Cover pipe and cover side remove to prevent vibration • Remove two screws.(for fixing cover pipe) • Pull up the cover side of desired connecting direc- 1) Open panel front tion, then cover side is separated.
  • Page 9: Sticking The Installation Guide Mapand Fixing Indoor Unit

    Installation Sticking the Installation Guide Map and Fixing Indoor Unit 1) Put an Installation Guide Map on the desired 7) Hang the hole of product at the upper screws. surface. (In this time, remove the map) I N S (Falling attention) T A L L A T INSTALLATION GUIDE MAP...
  • Page 10: Connection Of Piping

    Installation Connection of Piping • Preparing the indoor unit's piping and drain hose for • Tighten the flare nut with a wrench. installation through the wall. 1) Route the indoor tubing and the drain hose in the Open-end wrench (fixed) direction of rear left or right.
  • Page 11: Drain Piping

    Installation • Wrap the area which accommodates the rear piping • Bundle the piping and drain hose together by wrap- housing section with vinyl tape. ping them with vinyl tape for enough to cover where they fit into the rear piping housing section. Indoor Connection unit pipe...
  • Page 12: Front Panel Assembly

    Installation Front Panel Assembly 1) First, check the side cover assembly exactly. 2) Assemble connecting lead wire with control and first fix the upper part of panel front, then match the lower part of panel front Panel Front Connector 3) Drive two screws. Indoor Unit...
  • Page 13: Wiring Connection

    Installation Wiring Connection • Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in- dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No.
  • Page 14: Installation Of Remote Controller

    Installation Installation of Remote Controller HOW TO MOUNT ONTO A WALL HOW TO INSERT BATTERIES 1. Remove the battery cover from the remote controller. • Do not use rechargeable batteries, • Slide the cover according to the arrow direction. such batteries differ from standard dry cells in shape, dimensions, and per- 2.