E.4.5

Stacking installations

The following tables indicate the possible appliance combina-
tions for stacking installations.
OVENS 6 GN 1/1 – 6 GN 2/1
Posi-
Appliance / base type
tion
Maximum
OVEN 6 GN
total height
1/1
mm [inches]
OVEN 6 GN
electrical
1/1
models 1736
[68" 11/32]
gas models
1766 [69" 17/
1
32]
electrical
models 1976
[77" 51/64]
gas models
2006 [78" 31/
2
32]
or
OVEN 10 GN
electrical
1/1
models 1986
[78" 3/16]
gas models
2016 [79" 3/
8]
or
OPEN
1528 [60" 5/
2
SUPPORT
32]
or
NEUTRAL
1528 [60" 5/
2
CUPBOARD
32]
or
HOT CUP-
1528 [60" 5/
2
BOARD
32]
or
BLAST
1882 [74" 3/
CHILLER
32]
2
30kg
1.
Without riser
2.
With riser
OVENS 10 GN 1/1 – 10 GN 2/1
Posi-
Appliance / base type
tion
Maximum
OVEN 10 GN
total height
1/1
mm [inches]
OPEN
1778 [70"]
SUPPORT
or
NEUTRAL
1778 [70"]
CUPBOARD
or
HOT
1778 [70"]
CUPBOARD
or
BLAST
CHILLER 30kg
NOTE!
Feet are intended as adjusted at their nominal
height.
E.4.6

Fixing oven systems

The installations indicated in the tables above for safety
reasons MUST be fixed to the wall or to the floor by means
of the appropriate accessories included in the appliance or to
be ordered, according to your model (kit "Wall brackets" or kit
"Flanged feet", see accessory list).
24
Maximum
OVEN 6 GN
total height
2/1
[inches]
OVEN 6 GN
electrical
2/1
models 1736
1
1
[68" 11/32]
gas models
1766 [69" 17/
1
32]
electrical
models 1976
2
2
[77" 51/64]
gas models
2006 [78" 31/
2
32]
or
OVEN 10 GN
electrical
2/1
models 1986
[78" 3/16]
gas models
2016 [79" 3/
8]
OPEN
1528 [60" 5/
2
SUPPORT
32]
or
NEUTRAL
1528 [60" 5/
2
CUPBOARD
32]
or
HOT CUP-
1528 [60" 5/
2
BOARD
32]
Maximum
OVEN 10
total height
GN 2/1
mm [inches]
OPEN
1778 [70"]
SUPPORT
or
NEUTRAL
1778 [70"]
CUPBOARD
or
HOT CUP-
1778 [70"]
BOARD
IMPORTANT
The same safety provision shall be applied to floor
standing ovens, to ship and offshore oil plant
installations and to all installations where the
extraction or recirculation hood, available as acces-
sory, is staked on the oven.
6 - 10 GN models : Wall fixing with wall brackets
• Fix the stacked ovens to the wall by means of the 2 brackets.
See the figure below.
6 - 10 GN models : Floor fixing with flanged feet
If the stacked ovens cannot be fixed to the wall it is necessary
to fix them to the floor. Use the "Flanged feet" kit with 3 holes
base for fixing to the floor.
• undo the screws to remove the existing feet of the bottom
oven;
• replace them with those of the kit;
• screw the 4 screws (M5x14) in each foot to fix the stacked
ovens to the floor.
Ø10 (x3)