Panasonic YD-500KR Operating Instructions Manual page 41

Thyristor controlled mig/mag arc weldingpowersource
Hide thumbs Also See for YD-500KR:
Table of Contents

Advertisement

OTHER TROUBLE AND ERROES
Trouble shooting
Warning for safety
Prior to troubleshooting, be sure to turn off the switch box and welding machine and make
sure of safety.
Otherwise, it may lead to a serious accident affecting safety or the human body, such as
electric shock or burn.
Caution
Do not turn on the switch box with the top plate, side plates, or front panel removed from
the welding power source. Magnetic action may cause deformation of the equipment or
displacement/contact of the internal parts. Resulting in destruction of the parts or
deterioration of the functions/performance.
After finding out a cause by following the flow
chart, take a remedy according to the relevant
category below.
When the fuse is gone
After eliminating a cause(overload or
short-circuit), replace the fuse with a
specified one, referring to the Parts
List.
When the fuse goes again after turning on
the power, turn off the power and ask our
office for examination/repair.
When
the
printed
defective.
examination/repair.
When any parts other than those above are
defective.
Obtain relevant parts, referring to the
Parts List, and replace with new ones.
When other cause is likely
Correct any defective matters (erroneous
or insecure connection).
circuit
board
Ask
our
office
is
for
39
Motor
Power
Fu2
Fu1