Connecting 24 VAC / 36 VDC Power

Connect 24VAC +/- 10%, 50/60Hz or 36VDC +/- 10% to Connector X105 pins 1 and 2 as in the
figure that follows.
X105 Connector
Pin 1
Pin 2
Note: The AUTODOME camera will generally work with either polarity of 24VAC line/neutral,
and 36VDC (+) and 36VDC (-) as long as these lines are not connected to more than one
AUTODOME camera.
Caution!
Compliance with EN50130-4 Alarm Standard - CCTV for Security Applications
To meet the requirements of the EN50130-4 Alarm Standard, an ancillary uninterruptable
!
power (UPS) supply is necessary. The UPS must have a Transfer Time between 2-6 ms and a
Backup Runtime of greater than 5 seconds for the power level as specified on the product
datasheet.