en | Installing the camera outdoors
Additional wiring guidelines
Maintain the physical separation distance between the Cat5e/Cat6 shielded Ethernet cable
and high voltage/EMF sources. These are typical recommendations, but also refer to local
electrical codes.
Voltage range
For <600 VAC
For >600 VAC and <3 kV
For >3 kV
Use shielded cables for alarms, audio, or any other connections when applicable.
2023-02 | V01 |
1 Indoor main building
3 Surge suppression for indoor
equipment at cable entry
5 Install Cat5e/Cat6 shielded Ethernet cable such as F/UTP shielded cable with twisted
pairs (often referred to as FTP) or S/UTP braided shield with twisted pairs (often
referred to as STP) with shielded RJ45 connectors.
The cable must be routed through a permanently earthed liquid tight metal conduit
that is Earth-grounded across the entire span.
The cables must be a maximum length of 100 m (328 ft). Power and signal cables
must be in separate conduits with the correct physical separation distance between
them. (Refer to the section Additional wiring guidelines.)
6 Outdoor-rated midspan with shielded
RJ45 connections. Ground the metal
conduit to the midspan per the
installation instructions of the camera/
midspan.
8 Optional outdoor-rated network switch
or patch panel
10 Lightning Rod (Refer to the section
Lightning rod, down conductor, and
electrode.)
12 Lightning Rod Grounding Electrode
(Refer to the sections Lightning rod,
down conductor, and electrode and
Separate grounding electrodes.)
2 Network switch with shielded ports
4 Outdoor rated surge suppressor with
7 Equipment enclosure with AC power
9 Connect the Bus Bar to the Equipment
11 Down Conductor (Refer to the section
13 Equipment Grounding Electrode (Refer
Minimum separation distance
50 mm (2 in.)
1.5 m (5 ft)
3 m (10 ft)
Installation Manual
AUTODOME 7100i│AUTODOME 7100i IR
and grounding as recommended by the
manufacturer. All network cables must
be terminated with shielded RJ45
connectors.
shielded RJ45 connections that must
be mounted as close to the camera as
possible. Connect the ground per the
manufacturer's installation manual.
source for the midspan
Grounding Electrode. All equipment
must be bonded to this common bus
bar.
Lightning rod, down conductor, and
electrode.)
to the section Separate grounding
electrodes.)