Specifications
Type
Model No.
Vibration resistance
Shock resistance
SFF
(Safe Failure Fraction)
HFT (Hardware Fault
Tolerance)
Subsystem type
T1 (proof test interval)
Failure response time
Safety state
Emitter element
Connection method
Cable extension
Material
Accessories
Applicable standards
Notes: 1) The setting can be changed using the communication module SF4D-TM1 (option) and Configurator
Light Curtain software.
2) Because the control output (OSSD 1 / 2) must be OFF for at least 80ms, the ON response will be de-
layed more than 50ms when the light blocked time is less than 30ms.
3) When optical synchronization is selected, if the beam axes of both the top end and bottom end are
blocked, the ON response speed decreases by as much as 1 sec.
4) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0m.
5) Taking cable voltage drop and other factors into account, use a cable length as indicated below for the
source / sink current of the control output (OSSD 1 / 2).
Number of sub-
sensors
0
(no series connection)
1
2
3
4
Power cable: A bottom cap cable (option) combined with an extension cable (option)
144
10mm pitch type
SF4D-F□
10 to 55Hz, 0.75mm double amplitude for two hours each in X, Y, and Z directions
Malfunction resistance 10 to 55Hz, 0.75mm double amplitude 20 times each in X, Y, and Z directions
2
300m/s
(approx. 30G) 3 times each in X, Y, and Z directions
Malfunction resistance 100m/s
Infrared LED (peak emission wavelength: 850nm)
Total length of emitter / receiver can be extended up to 70m each using optional con-
nection cable (Note 5)
Enclosure: Aluminum, Detection surface: Polycarbonate / resin and SS304
Upper cap / lower cap: Nylon
SF4B-TR14 (test rod): 1 pc. SF4B-TR25 (test rod): 1 pc.
IEC 61496-1/2 (Type 4), ISO 13849-1: 2015 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
EN 61496-1/2 (Type 4), EN ISO 13849-1: 2015 (Category 4, PLe), EN 55011
EN 61000-6-2, EN 50178, JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4)
JIS C 0508-1 to 7 (SIL3), ANSI/UL 61496-1/2 (Type 4), CAN/CSA C22.2 No.14
CAN/CSA E61496-1/2
Control output (OSSD 1
/ 2) source / sink current
100mA
200mA
350mA
100mA
200mA
350mA
100mA
200mA
350mA
100mA
200mA
350mA
100mA
200mA
350mA
20mm pitch type
SF4D-H□
2
(approx. 10G) 1,000 times each in X, Y, and Z directions
99%
1
Type B (IEC 61508-2)
20 years
Within response time (OFF response)
Control output (OSSD 1 / 2) OFF state
By connector
Length of power cable
+ length of series
connection cable
Length of power cable
(total cable length)
70m or less
70m or less
10.5m or less
50m or less
50m or less
50m or less
50m or less
50m or less
50m or less
50m or less
50m or less
50m or less
25.5m or less
25.5m or less
25.5m or less
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
40mm pitch type
SF4D-A□
Cable
Length of series
connection cable
-
-
-
-
-
10.5m or less
-
-
Total cable length
10.5m or less
m i n u s t h e p o w e r
-
cable length
40.5m or less
10.5m or less
-
20.5m or less
10.5m or less
-
-
-