Properties of a DRIVE-CLiQ interface
Table 4-9  DRIVE-CLiQ interfaces X100 to X103
Property
Connector type
Cable type, inside the control cabinet
Cable type, outside the control cabinet
Blanking plug for closing unused DRIVE-CLiQ inter­
faces
NOTE
The maximum permissible cable length is 100 m.
Pin assignment of a DRIVE-CLiQ interface
Table 4-10  Pin assignment of DRIVE-CLiQ interfaces X100 to X103
View
B
A
SIMATIC Drive Controller
Equipment Manual, 11/2022, A5E46600370-AC
Pin Signal
Type of signal
name
1
TXP
Output
1
2
TXN
Output
3
RXP
Input
8
4
-
-
5
-
-
6
RXN
Input
7
-
-
8
-
-
A
+ (24 V)
Voltage Output Voltage supply for DRIVE-CLiQ,
B
M (0 V)
Voltage Output Ground for 24 V
4.5 DRIVE-CLiQ interfaces X100 to X103
Version
DRIVE-CLiQ connector (RJ45 socket)
DRIVE-CLiQ standard
MOTION CONNECT
Blanking plugs are included in the scope of delivery
of the SIMATIC Drive Controller.
Additional blanking plugs are available as accessor­
ies.
Meaning
Transmit data +
Transmit data -
Receive data +
Reserved; no connection
Reserved; no connection
Receive data -
Reserved; no connection
Reserved; no connection
≤ 450 mA