3.4 Mode of operation
Valve state
* through cavitation
Only a closed defective valve results in a high sound pressure level.
18
Valve position
intact
open
intact
closed
defective
open
defective
closed
Δp
Q
small
large
large
zero
small
large
large
medium
SITRANS DA400 for oscillating positive displacement pumps
Operating Instructions, 09/2008, A5E00841120-03
ƞ
L
small
small
small
small
small
small
large*
large