Parameter
EXT_UHF
LEN_ID
MEM_BANK
PSWD
EDIT_BLACKLIST_MODE
INVENTORY_DURATION
INVENTORY_DUR_UNIT
LOCK-TAG-
BANK_ACTION
LOCK-TAG-BANK_MASK
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
Data type
Default
value
STRUCT
--
SINT
0
SINT
3
DINT
0
SINT
0
DINT
0
DINT
0
DINT
0
DINT
0
4.6 Programming the Ident profile
Description
Structure for additional parameters
Length of the valid data in the "EPCID_UID" field.
Memory bank on the transponder
•
0x00 = RESERVED
•
0x01 = EPC
•
0x02 = TID
•
0x03 = USER
0x00 ≙ no password
Password for transponder access
Mode
•
0x00 = add EPC-ID
•
0x01 = add all "Observed" transponders
•
0x02 = delete EPC-ID
•
0x03 = delete all
Duration
Period of time or number of inventories or number of
"Observed" events
0x00 ≙ no inventory
Example:
0x01 ≙ one inventory
•
•
Unit for "DURATION"
•
0x00 = time [ms]
•
0x01 = inventories
•
0x02 = number of "Observed" events
Lock-Action (see "EPC Specification")
Lock-Mask (see "EPC Specification")
Configuring the instructions
75