4.5.2.4

Set_MV_Program

Using the "Set_MV_Program" instruction, you can change the program in a camera. The
required program number is transferred using the "PROGRAM" parameter.
Figure 4-8
Table 4- 17 Explanation for the instruction "Set_MV_Program"
Parameter
PROGRAM
4.5.3

Extended instructions

4.5.3.1

AdvancedCMD

Using the "AdvancedCmd" instruction, every command can be executed including
commands not represented by other instructions. This general structure can be used for
all commands and is intended only for trained users.
This instruction allows you to optionally execute a series of concatenated commands
with only one single call of the instruction. The instruction provides a CMD buffer for 10
commands for this. All chained commands must be entered starting at the first position
in the buffer. For every chained command, the "chained bit" must also be set in the CMD
structure. The "chained bit" is not set in the last command in the chain. You will find
further information on the "chained bit" in the section "Chaining (Page 95)".
The entire command structure must be specified in the "CMD" input parameter. You
create the structure for the "CMD" parameter in a data block.
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 07/2020, C79000-G8976-C410-04
Instruction "Set_MV_Program"
Data type
SINT
Default values
Description
0x01
Program number
Range of values: 0x01 ... 0x0F
Configuring the instructions
4.5 Programming instructions
37