FT2009-U1 / FT2009-R1
LED Annunciator-32 Zone
Product Manual
Characteristic
A6V10456393_enUS_c
2016-06-16
2 × 32 LEDs for 32 zones alarm/supervisory/trouble event display
l
Display of system fault and ground fault from the entire system
l
Communication with panel through UFP (individual address)
l
External 24V DC power source required from an UL listed/recognized for fire use,
l
regulated, power limited power supply
In total, up to 8 UFP type devices connected to a fire control panel
l
Manually activate / deactivate NAC's
l
Acknowledge and reset events from the entire system
l
Self test function
l
Flat, elegant housing
l
FT2007 built-in
24V DC
firealarmresources.com
Power
Trou ble
Groun d Faul t
Audibles On
Silenced
Acknowledge
Reset
Lamp Test
FT2008-U1
FT2008-U1
FT2009
24V DC
24V DC
Siemens Industry, Inc.
Building Technologies Division
Po wer
UFP
Trouble
Ground Fault
Audibles On
Silenced
Acknowledge
Reset
Lamp Test
FT2008

Advertisement

loading

Summary of Contents for Siemens FT2009-U1

  • Page 1 FT2009-U1 / FT2009-R1 LED Annunciator-32 Zone Product Manual Characteristic 2 × 32 LEDs for 32 zones alarm/supervisory/trouble event display Display of system fault and ground fault from the entire system Communication with panel through UFP (individual address) External 24V DC power source required from an UL listed/recognized for fire use,...
  • Page 2 Resets the fire control panel to quiescent condition. Lamp Test Test the LEDs and local buzzer. Key switch: The key switch is used for control of button operation. Lock key position Function Buttons locked. Buttons unlocked. Siemens Industry, Inc. A6V10456393_enUS_c Building Technologies Division 2016-06-16 firealarmresources.com...
  • Page 3 Connect to fire control panel FC901/FC2005, 19200 bps is required. EOL jumper: EOL jumper is used for setting terminal resistor of UFP. Jumper IN Terminal resistor is connected. Jump OUT Terminal resistor is not connected. Siemens Industry, Inc. A6V10456393_enUS_c Building Technologies Division 2016-06-16 firealarmresources.com...
  • Page 4 101592282 LED annunciator-32 Zone, red 3.748 lb · For Canadian applications, the “FT2009-U1”/“FT2009-R1” is deemed supplementary and can be used for display only. It must be housed in a ULC-S527 approved, locked, enclosure. · Not approved for UL/ULC MNS applications.